American Standard / AIR-SOURCE HEAT PUMP

4A6V0X36A1

PLATINUM 20 · XV20I · source records, page 8

212 published source records · source checked Sep 21, 2026

SEER2 range17.5–20.5BTU/Wh
HSPF2 range8–8.7BTU/Wh
Cooling capacity32,000–36,000BTU/h

Each efficiency range summarizes published EPA records for 4A6V0X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.5–20.5212 / 212
EER2 · BTU/Wh11.2–12.7212 / 212
HSPF2 · BTU/Wh8–8.7212 / 212
Cooling capacity · BTU/h32,000–36,000212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h29,800–35,400212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h24,400–29,000212 / 212
Heating capacity at 5°F / −15°C · BTU/h19,000–22,400212 / 212
COP at 5°F / −15°C1.6–1.92212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-410A (GWP:2088)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*BU36BS3+ furnace: S8V2B060M4PCAAHRI reference: 21069203719.508.50208001.78EPA 2473455 →
4PX*BU36BS3+ furnace: S8V2B080M4PCAAHRI reference: 21069203819.508.50208001.78EPA 2473457 →
4PX*BU36BS3+ furnace: L8V1B080U4VSA+RPAHRI reference: 21065297519.508.20208001.77EPA 2527006 →
4TXCB004DS3+ furnace: L8V1B080U4VSA+RPAHRI reference: 21065300719.508.20208001.78EPA 2527012 →
4TXCB004DS3+ furnace: L8V1B080U4VSB+RPAHRI reference: 21262982019.508.20208001.70EPA 2632827 →
4PX*BU36BS3+ furnace: L8V1B080U4VSB+RPAHRI reference: 21262979219.508.20208001.70EPA 2632862 →
4PX*CD36BS3+ furnace: S8V2C080M5PCBAHRI reference: 21425299219.508.00206001.60EPA 3412841 →
4PX*CD36BS3+ furnace: S8V2C080M5PDBAHRI reference: 21425299419.508.00206001.60EPA 3412843 →
4PX*CU36BS3+ furnace: S8V2C100M5PCBAHRI reference: 21425300819.508.50204001.80EPA 3412857 →
4PX*CU36BS3+ furnace: S8V2C100M5PDBAHRI reference: 21425301219.508.50204001.80EPA 3412860 →
4PX*CU36BS3+ furnace: S8V2C080M5PCBAHRI reference: 21425301419.508.50204001.70EPA 3412862 →
4PX*CU42BS3+ furnace: S8V2C080M5PCBAHRI reference: 21425301619.508.50204001.80EPA 3412864 →
4PX*CU36BS3+ furnace: S8V2C080M5PDBAHRI reference: 21425301019.508.50204001.70EPA 3412866 →
4PX*CU42BS3+ furnace: S8V2C080M5PDBAHRI reference: 21425302219.508.50204001.80EPA 3412871 →
4TXCB004DS3+ furnace: S8V2B080M4PDBAHRI reference: 21425303219.508.50208001.70EPA 3412880 →
4TXCB004DS3+ furnace: S8V2B060M4PDBAHRI reference: 21425303819.508.50208001.70EPA 3412887 →
4TXCB004DS3+ furnace: S8V2B060M4PCBAHRI reference: 21425304019.508.50208001.70EPA 3412889 →
4TXCB004DS3+ furnace: S8V2B080M4PCBAHRI reference: 21425304219.508.50208001.70EPA 3412891 →
4TXCC005DS3+ furnace: S8V2C100M5PCBAHRI reference: 21425304419.508.50204001.70EPA 3412893 →
4TXCC005DS3+ furnace: S8V2C080M5PCBAHRI reference: 21425304619.508.50204001.70EPA 3412894 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →