AZV9SA6010A*
AZV9SA
33 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for AZV9SA6010A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 33 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 33 / 33 |
| EER2 · BTU/Wh | 9.8–10.5 | 33 / 33 |
| HSPF2 · BTU/Wh | 8.5–9 | 33 / 33 |
| Cooling capacity · BTU/h | 52,000–54,000 | 33 / 33 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 52,500–54,000 | 33 / 33 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 33,400 | 33 / 33 |
| Heating capacity at 5°F / −15°C · BTU/h | 45,000–47,000 | 33 / 33 |
| COP at 5°F / −15°C | 1.8–1.9 | 33 / 33 |
| Equipment / loop type | HP - Split System | 33 / 33 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 33 / 33 |
| Compressor staging | Continuously variable | 33 / 33 |
| Connected capability | Yes | 33 / 33 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern AZV9SA6010A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 230 lb | AZV9S S-Series — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 40 A | AZV9S S-Series — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 34.4 A | AZV9S S-Series — product specifications · page 3 ↗ |
| Shipping weight | 265 lb | AZV9S S-Series — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | AZV9S S-Series — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
AHVE60DP1300A*Cold climate designationAHRI reference: 217989106 | 18.00 | 9.00 | 47000 | 1.90 | EPA 4518350 → |
AHVE60DP0300A*Cold climate designationAHRI reference: 217989141 | 18.00 | 9.00 | 47000 | 1.90 | EPA 4518386 → |
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 217989143 | 17.00 | 8.80 | 46000 | 1.90 | EPA 4518388 → |
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 217989145 | 17.00 | 8.80 | 46000 | 1.90 | EPA 4518390 → |
CA*EA6030*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 217989155 | 17.00 | 8.80 | 46000 | 1.90 | EPA 4518399 → |
CA*EA6030*3A*+ furnace: A*VT800805D*A*Cold climate designationAHRI reference: 217989157 | 17.00 | 8.80 | 46000 | 1.90 | EPA 4518402 → |
CA*EA6030*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 217989159 | 17.00 | 8.80 | 46000 | 1.90 | EPA 4518404 → |
CA*EA6030*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 217989161 | 17.00 | 8.80 | 46000 | 1.90 | EPA 4518406 → |
CA*EA6030*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 217989165 | 17.00 | 8.80 | 46000 | 1.90 | EPA 4518410 → |
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 217989170 | 17.00 | 8.80 | 46000 | 1.90 | EPA 4518415 → |
CA*EA6030*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 217989151 | 16.50 | 8.50 | 46000 | 1.90 | EPA 4518396 → |
CA*EA6030*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 217989153 | 16.50 | 8.80 | 46000 | 1.90 | EPA 4518400 → |
CA*EA6030*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 217989163 | 16.50 | 8.80 | 46000 | 1.90 | EPA 4518408 → |
CA*EA6030*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 217989169 | 16.50 | 8.80 | 46000 | 1.90 | EPA 4518414 → |
CHPEA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 217989142 | 16.00 | 8.50 | 45000 | 1.80 | EPA 4518387 → |
CHPEA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 217989144 | 16.00 | 8.50 | 45000 | 1.80 | EPA 4518389 → |
CHPEA6030*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 217989146 | 16.00 | 8.50 | 45000 | 1.80 | EPA 4518391 → |
CA*EA6030*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 217989147 | 16.00 | 8.50 | 46000 | 1.90 | EPA 4518392 → |
CHPEA6030*3A*+ furnace: A*VT961005DNA*Cold climate designationAHRI reference: 217989148 | 16.00 | 8.50 | 45000 | 1.80 | EPA 4518393 → |
CA*EA6030*3A*+ furnace: A*VT961005DNA*Cold climate designationAHRI reference: 217989149 | 16.00 | 8.50 | 46000 | 1.90 | EPA 4518394 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
AZV9S S-Series — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →