AZV9SA4810A*
AZV9SA
35 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for AZV9SA4810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 35 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.2–18 | 35 / 35 |
| EER2 · BTU/Wh | 10.5–11.7 | 35 / 35 |
| HSPF2 · BTU/Wh | 8.5–9 | 35 / 35 |
| Cooling capacity · BTU/h | 45,000–46,000 | 35 / 35 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–48,000 | 35 / 35 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–30,000 | 35 / 35 |
| Heating capacity at 5°F / −15°C · BTU/h | 44,000 | 35 / 35 |
| COP at 5°F / −15°C | 1.8–1.9 | 35 / 35 |
| Equipment / loop type | HP - Split System | 35 / 35 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 35 / 35 |
| Compressor staging | Continuously variable | 35 / 35 |
| Connected capability | Yes | 35 / 35 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern AZV9SA4810A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 230 lb | AZV9S S-Series — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 40 A | AZV9S S-Series — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 34.4 A | AZV9S S-Series — product specifications · page 3 ↗ |
| Shipping weight | 265 lb | AZV9S S-Series — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | AZV9S S-Series — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
AHVE60DP1300A*Cold climate designationAHRI reference: 217989109 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518354 → |
AHVE60DP0300A*Cold climate designationAHRI reference: 217989235 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518482 → |
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 217989236 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518483 → |
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 217989238 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518485 → |
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 217989240 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518487 → |
CA*EA6030*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 217989250 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518496 → |
CA*EA6030*3A*+ furnace: A*VT800805D*A*Cold climate designationAHRI reference: 217989252 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518499 → |
CA*EA6030*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 217989254 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518501 → |
CA*EA6030*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 217989256 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518503 → |
CA*EA6030*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 217989260 | 18.00 | 9.00 | 44000 | 1.90 | EPA 4518507 → |
CHPEA4830*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 217989237 | 17.50 | 8.50 | 44000 | 1.80 | EPA 4518484 → |
CA*EA6030*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 217989242 | 17.50 | 9.00 | 44000 | 1.90 | EPA 4518489 → |
CA*EA6030*3A*+ furnace: A*VT961005DNA*Cold climate designationAHRI reference: 217989244 | 17.50 | 9.00 | 44000 | 1.90 | EPA 4518491 → |
CA*EA6030*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 217989246 | 17.50 | 9.00 | 44000 | 1.90 | EPA 4518493 → |
CA*EA6030*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 217989248 | 17.50 | 9.00 | 44000 | 1.90 | EPA 4518495 → |
CA*EA6030*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 217989258 | 17.50 | 9.00 | 44000 | 1.90 | EPA 4518505 → |
CA*EA6030*3A*+ furnace: A*VM971205DNA*Cold climate designationAHRI reference: 217989262 | 17.50 | 9.00 | 44000 | 1.90 | EPA 4518509 → |
CA*EA6030*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 217989264 | 17.50 | 9.00 | 44000 | 1.90 | EPA 4518511 → |
CA*EA6030*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 217989266 | 17.50 | 9.00 | 44000 | 1.90 | EPA 4518513 → |
CA*EA6030*3A*+ furnace: A*VC961205DNB*Cold climate designationAHRI reference: 218003041 | 17.50 | 9.00 | 44000 | 1.90 | EPA 4518551 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
AZV9S S-Series — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →