Amana / AIR-SOURCE HEAT PUMP

AZV9SA241CA*

AZV9SA

45 published source records · source checked Sep 21, 2026

SEER2 range16.9–21BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity23,000–24,000BTU/h

Each efficiency range summarizes published EPA records for AZV9SA241CA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 45 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.9–2145 / 45
EER2 · BTU/Wh11.7–12.245 / 45
HSPF2 · BTU/Wh8.5–1045 / 45
Cooling capacity · BTU/h23,000–24,00045 / 45
Heating capacity at 47°F / 8.3°C · BTU/h21,000–24,00045 / 45
Heating capacity at 17°F / −8.3°C · BTU/h21,000–24,00045 / 45
Heating capacity at 5°F / −15°C · BTU/h21,000–24,00045 / 45
COP at 5°F / −15°C2–2.445 / 45
Equipment / loop typeHP - Split System45 / 45
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)45 / 45
Compressor stagingContinuously variable45 / 45
Connected capabilityYes45 / 45

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern AZV9SA241CA*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight230 lbAZV9S S-Series — product specifications · page 3
Maximum overcurrent protection20 AAZV9S S-Series — product specifications · page 3
Minimum circuit ampacity17.4 AAZV9S S-Series — product specifications · page 3
Shipping weight265 lbAZV9S S-Series — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseAZV9S S-Series — product specifications · page 3

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 21669979321.0010.00240002.40EPA 3894061
AHVE48CP1300A*Cold climate designationAHRI reference: 21669984319.209.20224002.10EPA 3894013
AHVE48CP0300A*Cold climate designationAHRI reference: 21669984419.209.20224002.10EPA 3894014
CA*EA4830*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21669984619.209.20220002.00EPA 3894016
CA*EA4830*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 21669984819.209.20220002.00EPA 3894018
CA*EA4830*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 21669985019.209.20220002.00EPA 3894020
CA*EA4830*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 21669985219.209.20220002.00EPA 3894022
CA*EA4830*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 21669985419.209.20220002.00EPA 3894024
CA*EA4830*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 21669985619.209.20220002.00EPA 3894026
CA*EA4830*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 21669985819.209.20220002.00EPA 3894028
CA*EA4830*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 21669986019.209.20220002.00EPA 3894030
CA*EA4830*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 21669986219.209.20220002.00EPA 3894032
CA*EA4830*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 21669986419.209.20220002.00EPA 3894034
CA*EA4830*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758947219.209.20220002.00EPA 4497801
CA*EA4830*3A*+ furnace: A*VT960803BNA*Cold climate designationAHRI reference: 21788307819.209.20220002.00EPA 4512479
CA*EA4830*3A*+ furnace: A*VT800803B*A*Cold climate designationAHRI reference: 21788308219.209.20220002.00EPA 4512505
CA*EA4830*3A*+ furnace: A*VT800604B*A*Cold climate designationAHRI reference: 21788308419.209.20220002.00EPA 4512507
CA*EA4830*3A*+ furnace: A*VT960603BNA*Cold climate designationAHRI reference: 21788308019.209.20220002.00EPA 4512509
CA*EA4830*3A*+ furnace: A*VT800603B*A*Cold climate designationAHRI reference: 21788308619.209.20220002.00EPA 4512510
CA*EA4830*3A*+ furnace: A*VS960603BUA*Cold climate designationAHRI reference: 21788308819.209.20220002.00EPA 4512516

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

AZV9S S-Series — product specificationsManufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →