AZV7SA4210A*
AZV7SA · source records, page 3
62 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for AZV7SA4210A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 62 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–17.5 | 62 / 62 |
| EER2 · BTU/Wh | 10 | 62 / 62 |
| HSPF2 · BTU/Wh | 8.6–8.8 | 62 / 62 |
| Cooling capacity · BTU/h | 40,500–41,000 | 62 / 62 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 41,000 | 62 / 62 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000 | 62 / 62 |
| Heating capacity at 5°F / −15°C · BTU/h | 31,000 | 62 / 62 |
| COP at 5°F / −15°C | 2 | 62 / 62 |
| Equipment / loop type | HP - Split System | 62 / 62 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 62 / 62 |
| Compressor staging | Continuously variable | 62 / 62 |
| Connected capability | No | 62 / 62 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern AZV7SA4210A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 179 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 40 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 37.5 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Shipping weight | 198 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | AZV7S S-SERIES — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CHPEA6030*3A*+ furnace: A*VC961205DNB*Cold climate designationAHRI reference: 215487742 | 17.00 | 8.60 | 31000 | 2.00 | EPA 3628026 → |
CA*EA6030*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 215434270 | 16.50 | 8.80 | 31000 | 2.00 | EPA 3625558 → |
CA*EA6030*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 215434271 | 16.50 | 8.80 | 31000 | 2.00 | EPA 3625559 → |
CA*EA6030*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 215434274 | 16.50 | 8.80 | 31000 | 2.00 | EPA 3625562 → |
CA*EA6030*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 215434279 | 16.50 | 8.80 | 31000 | 2.00 | EPA 3625567 → |
CA*EA6030*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 215434280 | 16.50 | 8.80 | 31000 | 2.00 | EPA 3625568 → |
CHPEA4830*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 215434283 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625571 → |
CHPEA4830*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 215434284 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625572 → |
CHPEA4830*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 215434287 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625575 → |
CHPEA4830*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 215434292 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625580 → |
CHPEA4830*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 215434293 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625581 → |
CHPEA6030*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 215434296 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625584 → |
CHPEA6030*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 215434297 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625585 → |
CHPEA6030*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 215434300 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625588 → |
CHPEA6030*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 215434305 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625593 → |
CHPEA6030*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 215434306 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3625594 → |
CA*EA6030*3A*+ furnace: A*VC960804CNB*Cold climate designationAHRI reference: 215487720 | 16.50 | 8.80 | 31000 | 2.00 | EPA 3627974 → |
CA*EA6030*3A*+ furnace: A*VC961005CNB*Cold climate designationAHRI reference: 215487721 | 16.50 | 8.80 | 31000 | 2.00 | EPA 3627975 → |
CHPEA4830*3A*+ furnace: A*VC960804CNB*Cold climate designationAHRI reference: 215487730 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3627984 → |
CHPEA4830*3A*+ furnace: A*VC961005CNB*Cold climate designationAHRI reference: 215487731 | 16.50 | 8.60 | 31000 | 2.00 | EPA 3627985 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
AZV7S S-SERIES — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →