Amana / AIR-SOURCE HEAT PUMP

AZV7SA3610A*

AZV7SA · source records, page 3

69 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–8.8BTU/Wh
Cooling capacity34,000–35,000BTU/h

Each efficiency range summarizes published EPA records for AZV7SA3610A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 69 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1969 / 69
EER2 · BTU/Wh10–10.569 / 69
HSPF2 · BTU/Wh8.1–8.869 / 69
Cooling capacity · BTU/h34,000–35,00069 / 69
Heating capacity at 47°F / 8.3°C · BTU/h34,800–35,00069 / 69
Heating capacity at 17°F / −8.3°C · BTU/h22,00069 / 69
Heating capacity at 5°F / −15°C · BTU/h28,000–29,00069 / 69
COP at 5°F / −15°C269 / 69
Equipment / loop typeHP - Split System69 / 69
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)69 / 69
Compressor stagingContinuously variable69 / 69
Connected capabilityNo · Yes69 / 69

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern AZV7SA3610A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight168 lbAZV7S S-SERIES — product specifications · page 3 ↗
Maximum overcurrent protection35 AAZV7S S-SERIES — product specifications · page 3 ↗
Minimum circuit ampacity31.8 AAZV7S S-SERIES — product specifications · page 3 ↗
Shipping weight185 lbAZV7S S-SERIES — product specifications · page 3 ↗
Voltage / phase at 60 Hz208-230/1 V / phaseAZV7S S-SERIES — product specifications · page 3 ↗

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CHPEA4830*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 21543418818.508.10284002.00EPA 3625476 →
CHPEA4830*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 21543418918.508.10284002.00EPA 3625477 →
CHPEA4830*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 21543419018.508.10284002.00EPA 3625478 →
CHPEA4830*3A*+ furnace: A*VT800805D*A*Cold climate designationAHRI reference: 21543419118.508.10284002.00EPA 3625479 →
CHPEA4830*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 21543419218.508.10284002.00EPA 3625480 →
CHPEA4830*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 21543419318.508.10284002.00EPA 3625481 →
CHPEA4830*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 21543419418.508.10284002.00EPA 3625482 →
CHPEA4830*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 21543419518.508.10284002.00EPA 3625483 →
CHPEA4830*3A*+ furnace: A*VM971205DNA*Cold climate designationAHRI reference: 21543419618.508.10284002.00EPA 3625484 →
CHPEA4830*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 21543419718.508.10284002.00EPA 3625485 →
CHPEA4830*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 21543419818.508.10284002.00EPA 3625486 →
CA*EA4830*3A*+ furnace: A*VC961205DNB*Cold climate designationAHRI reference: 21548768918.508.50284002.00EPA 3629122 →
CA*EA4830*3A*+ furnace: A*VC961005CNB*Cold climate designationAHRI reference: 21548769018.508.50284002.00EPA 3629123 →
CA*EA4830*3A*+ furnace: A*VC960804CNB*Cold climate designationAHRI reference: 21548769118.508.50284002.00EPA 3629124 →
CHPEA4830*3A*+ furnace: A*VC961205DNB*Cold climate designationAHRI reference: 21548770318.508.10284002.00EPA 3629136 →
CHPEA4830*3A*+ furnace: A*VC961005CNB*Cold climate designationAHRI reference: 21548770418.508.10284002.00EPA 3629137 →
CHPEA4830*3A*+ furnace: A*VC960804CNB*Cold climate designationAHRI reference: 21548770518.508.10284002.00EPA 3629139 →
CA*EA6030*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 21543418418.008.50284002.00EPA 3625472 →
CA*EA4830*3A*+ furnace: A*VT800603B*A*Cold climate designationAHRI reference: 21775508318.008.10284002.00EPA 4512455 →
CA*EA4830*3A*+ furnace: A*VT800803B*A*Cold climate designationAHRI reference: 21775508418.008.10284002.00EPA 4512456 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

AZV7S S-SERIES — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →