Amana / AIR-SOURCE HEAT PUMP

AZV6SA1810A*

AZV6SA · source records, page 2

73 published source records · source checked Sep 21, 2026

SEER2 range16–19BTU/Wh
HSPF2 range8.5–8.8BTU/Wh
Cooling capacity17,000–17,100BTU/h

Each efficiency range summarizes published EPA records for AZV6SA1810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 73 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1973 / 73
EER2 · BTU/Wh11–1273 / 73
HSPF2 · BTU/Wh8.5–8.873 / 73
Cooling capacity · BTU/h17,000–17,10073 / 73
Heating capacity at 47°F / 8.3°C · BTU/h16,800–17,40073 / 73
Heating capacity at 17°F / −8.3°C · BTU/h10,600–10,80073 / 73
Heating capacity at 5°F / −15°C · BTU/h12,600–13,00073 / 73
COP at 5°F / −15°C2–2.173 / 73
Equipment / loop typeHP - Split System73 / 73
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)73 / 73
Compressor stagingContinuously variable73 / 73
Connected capabilityNo · Yes73 / 73

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern AZV6SA1810A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight122 lbAZV6S S-SERIES — product specifications · page 3 ↗
Maximum overcurrent protection15 AAZV6S S-SERIES — product specifications · page 3 ↗
Minimum circuit ampacity12.8 AAZV6S S-SERIES — product specifications · page 3 ↗
Shipping weight137 lbAZV6S S-SERIES — product specifications · page 3 ↗
Voltage / phase at 60 Hz208-230/1 V / phaseAZV6S S-SERIES — product specifications · page 3 ↗

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CA*EA3022*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 21543968919.008.80130002.10EPA 3627735 →
CA*EA2418*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 21543969019.008.80130002.10EPA 3627736 →
CHPEA2422*3A*+ furnace: A*VT800803B*A*Cold climate designationAHRI reference: 21543969119.008.80130002.10EPA 3627737 →
CA*EA2418*3A*+ furnace: A*VT800803B*A*Cold climate designationAHRI reference: 21543969319.008.80130002.10EPA 3627738 →
CA*EA3022*3A*+ furnace: A*VT800803B*A*Cold climate designationAHRI reference: 21543969219.008.80130002.10EPA 3627739 →
CHPEA2422*3A*+ furnace: A*VT800604B*A*Cold climate designationAHRI reference: 21543969419.008.80130002.10EPA 3627740 →
CA*EA3022*3A*+ furnace: A*VT800604B*A*Cold climate designationAHRI reference: 21543969519.008.80130002.10EPA 3627741 →
CA*EA2418*3A*+ furnace: A*VT800604B*A*Cold climate designationAHRI reference: 21543969619.008.80130002.10EPA 3627742 →
CHPEA2422*3A*+ furnace: A*VT800603B*A*Cold climate designationAHRI reference: 21543969719.008.80130002.10EPA 3627743 →
CA*EA3022*3A*+ furnace: A*VT800603B*A*Cold climate designationAHRI reference: 21543969819.008.80130002.10EPA 3627744 →
CA*EA2418*3A*+ furnace: A*VT800603B*A*Cold climate designationAHRI reference: 21543969919.008.80130002.10EPA 3627745 →
CA*EA3022*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 21543970019.008.80130002.10EPA 3627746 →
CA*EA2418*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 21543970119.008.80130002.10EPA 3627747 →
CHPEA2422*3A*+ furnace: A*VS960603BUA*Cold climate designationAHRI reference: 21543970219.008.80130002.10EPA 3627748 →
CA*EA3022*3A*+ furnace: A*VS960603BUA*Cold climate designationAHRI reference: 21543970319.008.80130002.10EPA 3627749 →
CA*EA3022*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 21543970519.008.80130002.10EPA 3627750 →
CA*EA2418*3A*+ furnace: A*VS960603BUA*Cold climate designationAHRI reference: 21543970419.008.80130002.10EPA 3627751 →
CA*EA2418*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 21543970619.008.80130002.10EPA 3627752 →
CHPEA2422*3A*+ furnace: A*VS800604BUA*Cold climate designationAHRI reference: 21543970719.008.80130002.10EPA 3627753 →
CA*EA3022*3A*+ furnace: A*VS800604BUA*Cold climate designationAHRI reference: 21543970819.008.80130002.10EPA 3627754 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

AZV6S S-SERIES — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values