7SCP18V60P-**A
7SCP18V Series · source records, page 9
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7SCP18V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 191 / 191 |
| EER2 · BTU/Wh | 9.6–11.7 | 191 / 191 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 191 / 191 |
| Cooling capacity · BTU/h | 42,500–55,500 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–45,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 191 / 191 |
| COP at 5°F / −15°C | 1.75–1.95 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 191 / 191 |
| Compressor staging | Continuously variable | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH48CX-**+TDR+ furnace: 97G2UH090CV20*Cold climate designationAHRI reference: 217509392 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4438998 → |
7E[C,U]50/60CX-**+TDR+ furnace: 80G1UH090CE20*Cold climate designationAHRI reference: 217509396 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4438999 → |
7ED42BX-**+TDR+ furnace: 97G2DF070BV16*Cold climate designationAHRI reference: 217509147 | 16.00 | 9.00 | 40000 | 1.85 | EPA 4439036 → |
7EH48CX-**+TDR+ furnace: 92G1UH110CE20*Cold climate designationAHRI reference: 217509520 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4439069 → |
7EH51CX-**+TDR+ furnace: 80G2UH110CV20*Cold climate designationAHRI reference: 217897356 | 16.00 | 8.50 | 40500 | 1.85 | EPA 4512269 → |
7EH51CX-**+TDR+ furnace: 95G1UH100CE20X*Cold climate designationAHRI reference: 217897362 | 16.00 | 8.50 | 40500 | 1.85 | EPA 4512282 → |
7E[C,U]50/60CX-**+TDR+ furnace: 80G2UH110CE20*Cold climate designationAHRI reference: 217509400 | 15.90 | 8.10 | 40500 | 1.80 | EPA 4438381 → |
7EH48CX-**+TDR+ furnace: 80G2UH110CE16*Cold climate designationAHRI reference: 217509514 | 15.90 | 8.50 | 39500 | 1.80 | EPA 4438392 → |
7EH42CX-**+TDR+ furnace: 95G1UH100CE20X*Cold climate designationAHRI reference: 217509386 | 15.90 | 8.50 | 40000 | 1.80 | EPA 4438396 → |
7EH48CX-**+TDR+ furnace: 80G2UH110CE20L*Cold climate designationAHRI reference: 217509389 | 15.90 | 8.50 | 39500 | 1.80 | EPA 4438399 → |
7EH50/60CX-**+TDR+ furnace: 80G1UH100CE20X*Cold climate designationAHRI reference: 217509394 | 15.90 | 8.50 | 41000 | 1.85 | EPA 4438408 → |
7E[C,U]50/60CX-**+TDR+ furnace: 80G2UH110CE20L*Cold climate designationAHRI reference: 217509399 | 15.90 | 8.10 | 40500 | 1.80 | EPA 4438412 → |
7E[C,U]50/60CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217509527 | 15.90 | 8.10 | 41000 | 1.75 | EPA 4438954 → |
7EH48CX-**+TDR+ furnace: 80G2UH110CE20*Cold climate designationAHRI reference: 217509390 | 15.90 | 8.50 | 39500 | 1.80 | EPA 4438995 → |
7EH51CX-**+TDR+ furnace: 80G1UH100CE20X*Cold climate designationAHRI reference: 217897344 | 15.90 | 8.50 | 41000 | 1.85 | EPA 4512274 → |
7EH48CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217509519 | 15.80 | 8.50 | 40000 | 1.80 | EPA 4438395 → |
7E[C,U]50/60CX-**+TDR+ furnace: 97G2UH090CV20*Cold climate designationAHRI reference: 217509403 | 15.70 | 8.10 | 41000 | 1.75 | EPA 4438383 → |
7EH48CX-**+TDR+ furnace: 96G1UH110CE20*Cold climate designationAHRI reference: 217509393 | 15.70 | 8.50 | 39500 | 1.80 | EPA 4438407 → |
7E[C,U]50/60CX-**+TDR+ furnace: 95G1UH100CE20X*Cold climate designationAHRI reference: 217509401 | 15.70 | 8.10 | 41000 | 1.75 | EPA 4438984 → |
7E[C,U]50/60CX-**+TDR+ furnace: 96G1UH110CE20*Cold climate designationAHRI reference: 217509404 | 15.70 | 8.10 | 41500 | 1.75 | EPA 4438985 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →