Each efficiency range summarizes published EPA records for 7SCP18V24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 130 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 130 / 130 |
| EER2 · BTU/Wh | 11–12.3 | 130 / 130 |
| HSPF2 · BTU/Wh | 8.5–10 | 130 / 130 |
| Cooling capacity · BTU/h | 23,200–24,200 | 130 / 130 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,800–24,800 | 130 / 130 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,200 | 130 / 130 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–23,400 | 130 / 130 |
| COP at 5°F / −15°C | 1.75–1.85 | 130 / 130 |
| Equipment / loop type | HP - Split System | 130 / 130 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 130 / 130 |
| Compressor staging | Continuously variable | 130 / 130 |
| Connected capability | No | 130 / 130 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]36BX-**+TDR+ furnace: 80G2UH090BE12*Cold climate designationAHRI reference: 217509416 | 17.15 | 9.00 | 20400 | 1.85 | EPA 4438413 → |
7E[C,U]36BX-**+TDR+ furnace: 92G1UH045BE12*Cold climate designationAHRI reference: 217509421 | 17.15 | 9.00 | 20800 | 1.80 | EPA 4438417 → |
7EH30BX-**+TDR+ furnace: 80G2UH090BE12*Cold climate designationAHRI reference: 217509432 | 17.15 | 9.00 | 20600 | 1.80 | EPA 4439061 → |
7E[C,U]36AX-**+TDR+ furnace: 80G2UH070AE12*Cold climate designationAHRI reference: 217509177 | 17.10 | 9.00 | 20400 | 1.85 | EPA 4438190 → |
7EH30BX-**+TDR+ furnace: 92G1UH030BE12*Cold climate designationAHRI reference: 217509436 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4438421 → |
7E[C,U]36AX-**+TDR+ furnace: 80G2UH070AE12L*Cold climate designationAHRI reference: 217509176 | 17.10 | 9.00 | 20400 | 1.85 | EPA 4439017 → |
7EH24BX-**+TDR+ furnace: 96G1UH030BE08*Cold climate designationAHRI reference: 217509427 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4439053 → |
7EH30BX-**+TDR+ furnace: 92G1UH045BE12*Cold climate designationAHRI reference: 217509437 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4439064 → |
7E[C,U]36AX-**+TDR+ furnace: 80G2UH070AV12*Cold climate designationAHRI reference: 217509173 | 17.05 | 9.00 | 20800 | 1.85 | EPA 4438188 → |
7E[C,U]30AX-**+TDR+ furnace: 80G1UH040AE12X*Cold climate designationAHRI reference: 217509159 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4438204 → |
7E[C,U]30AX-**+TDR+ furnace: 80G1UH060AE12X*Cold climate designationAHRI reference: 217509160 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4438205 → |
7E[C,U]30BX-**+TDR+ furnace: 96G1UH030BE08*Cold climate designationAHRI reference: 217509411 | 17.00 | 9.00 | 20800 | 1.80 | EPA 4438303 → |
7ED24BX-**+TDR+ furnace: 92G1DF070BE12*Cold climate designationAHRI reference: 217509441 | 17.00 | 9.40 | 21000 | 1.80 | EPA 4438334 → |
7E[C,U]30BX-**+TDR+ furnace: 92G1UH070BE12*Cold climate designationAHRI reference: 217509414 | 17.00 | 9.00 | 20800 | 1.80 | EPA 4438969 → |
7AH2AE24PX-**Cold climate designationAHRI reference: 217509115 | 17.00 | 9.50 | 22600 | 1.85 | EPA 4439038 → |
7EH24AX-**+TDR+ furnace: 80G1UH060AE12X*Cold climate designationAHRI reference: 217509190 | 16.95 | 9.00 | 21000 | 1.80 | EPA 4438158 → |
7E[C,U]30BX-**+TDR+ furnace: 97G2UH045BV12*Cold climate designationAHRI reference: 217509122 | 16.95 | 9.00 | 20800 | 1.80 | EPA 4438173 → |
7EH24AX-**+TDR+ furnace: 80G1UH040AE12X*Cold climate designationAHRI reference: 217509189 | 16.95 | 9.00 | 21000 | 1.80 | EPA 4439023 → |
7ED24BX-**+TDR+ furnace: 92G1DF045BE12*Cold climate designationAHRI reference: 217509440 | 16.90 | 9.40 | 21000 | 1.80 | EPA 4438333 → |
7E[C,U]30AX-**+TDR+ furnace: 80G1UH045AE12*Cold climate designationAHRI reference: 217509165 | 16.85 | 9.00 | 20800 | 1.80 | EPA 4438100 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.