ALLIED / AIR-SOURCE HEAT PUMP

7HP19V60P-**A

7HP19V SERIES · 7HP19V Series · A7HP19V Series · source records, page 3

85 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 7HP19V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1885 / 85
EER2 · BTU/Wh11–11.785 / 85
HSPF2 · BTU/Wh7.8–985 / 85
Cooling capacity · BTU/h46,000–48,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h45,000–50,50085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h27,600–32,60085 / 85
Heating capacity at 5°F / −15°C · BTU/h21,800–29,80085 / 85
COP at 5°F / −15°C1.8–2.0685 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)85 / 85
Compressor stagingContinuously variable85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH48CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21722230317.507.80236001.80EPA 4012535
7EH51CX-**+TDRAHRI reference: 21745545217.508.10290001.90EPA 4047352
7ED60DX-**+TDR+ furnace: 97G2DF110CE20*AHRI reference: 21746486017.508.50298001.92EPA 4469546
7E[C,U]50/60CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21751285417.507.80238001.86EPA 4469698
7ED48CX-**+TDR+ furnace: 97G2DF090CV20*AHRI reference: 21751286117.508.10248001.88EPA 4469699
7ED48CX-**+TDR+ furnace: 97G2DF110CV20*AHRI reference: 21751286217.508.10248001.88EPA 4469700
7ED48CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21751286317.508.10246001.90EPA 4469701
7EH51CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21751287117.508.10290001.90EPA 4469702
7EH51CX-**+TDR+ furnace: 80G2UH110CV20**AHRI reference: 21751339117.508.10290001.90EPA 4469800
7EH51CX-**+TDR+ furnace: 97G2UH090CV20**AHRI reference: 21751339217.508.00292001.90EPA 4469801
7EH51CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21746484717.508.20290001.90EPA 4470161
7EH51CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21746484817.508.20290001.90EPA 4470165
7EH51CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21746485017.508.20286001.90EPA 4470173
7EH51CX-**+TDR+ furnace: 97G2UH110CV20*AHRI reference: 21746485417.508.10290001.92EPA 4470227
7EH51CX-**+TDR+ furnace: EFV16CCP-**AHRI reference: 21867197617.508.10290001.90EPA 4673183
7ED48CX-**+TDR+ furnace: EFV16CCP-**AHRI reference: 21867197317.508.10246001.90EPA 4673184
7E[C,U]50/60CX-**+TDR+ furnace: EFV16CCP-**AHRI reference: 21867197017.507.80238001.86EPA 4673185
7E[C,U]49CX-**+TDR+ furnace: 97G1UH080CE16*AHRI reference: 21879196717.509.00244001.96EPA 4706672
7E[C,U]50/60CX-**+TDR+ furnace: 80G1UH090CE20*AHRI reference: 21722227117.008.20232001.88EPA 4012432
7E[C,U]50/60CX-**+TDR+ furnace: 97G2UH110CE20*AHRI reference: 21722228017.008.20234001.86EPA 4012514

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.