ALLIED / AIR-SOURCE HEAT PUMP

7HP19V36P-**A

7HP19V SERIES · 7HP19V Series · A7HP19V Series · source records, page 9

198 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,800BTU/h

Each efficiency range summarizes published EPA records for 7HP19V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20198 / 198
EER2 · BTU/Wh11–13.2198 / 198
HSPF2 · BTU/Wh7.8–8.5198 / 198
Cooling capacity · BTU/h21,600–35,800198 / 198
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000198 / 198
Heating capacity at 17°F / −8.3°C · BTU/h13,900–23,000198 / 198
Heating capacity at 5°F / −15°C · BTU/h12,100–17,700198 / 198
COP at 5°F / −15°C1.48–2.2198 / 198
Equipment / loop typeHP - Split System198 / 198
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)198 / 198
Compressor stagingContinuously variable198 / 198
Connected capabilityNo198 / 198

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]36BX-**+TDR+ furnace: 80G1UH080BE16X*AHRI reference: 21722222416.508.20148001.92EPA 4012684
7EH36CX-**+TDR+ furnace: 97G2UH090CE16*AHRI reference: 21722226516.508.20163002.08EPA 4012695
7E[C,U]30BX-**+TDRAHRI reference: 21745530616.508.00144001.82EPA 4047282
7E[C,U]30AX-**+TDRAHRI reference: 21745536116.508.00144001.82EPA 4048318
7EH30BX-**+TDR+ furnace: 96G1UH045BE12*AHRI reference: 21746490716.508.20153001.88EPA 4469479
7EH30BX-**+TDR+ furnace: 97G2UH045BE12*AHRI reference: 21746491916.508.50152001.88EPA 4469491
7ED30/36CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21751282016.507.80165002.10EPA 4469685
7EH30BX-**+TDR+ furnace: 95G1UH040BE12X*AHRI reference: 21746489616.508.20153001.88EPA 4470235
7EH30BX-**+TDR+ furnace: 95G1UH060BE12X*AHRI reference: 21746489716.508.20153001.88EPA 4470239
7ED30/36CX-**+TDR+ furnace: EFV16CCP-**AHRI reference: 21867195916.507.80165002.10EPA 4673191
7EH36CX-**+TDR+ furnace: 97G1UH080CE16*AHRI reference: 21879195816.508.10173002.04EPA 4706681
7E[C,U]30/36BX-**+TDR+ furnace: 80G2UH090BE16*AHRI reference: 21722224916.008.00163001.92EPA 4012494
7E[C,U]30/36BX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21722225116.008.00163001.92EPA 4012495
7E[C,U]30/36BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21722225216.008.00163001.92EPA 4012497
7E[C,U]30/36CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21722225416.008.10163001.92EPA 4012498
7EH36CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21722225816.008.10164002.08EPA 4012502
7EH36CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21722225916.008.10164002.08EPA 4012503
7E[C,U]30/36BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 21722225016.008.00163001.92EPA 4012693
7E[C,U]30/36CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21722225316.008.00162001.94EPA 4012694
7ED30/36CX-**+TDR+ furnace: 97G2DF090CE16*AHRI reference: 21746483116.008.00164002.10EPA 4470130

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.