ALLIED / AIR-SOURCE HEAT PUMP

7HP14F30P-**A

7HP14F SERIES · 7HP14F Series

30 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.5–8.2BTU/Wh
Cooling capacity28,800–30,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 30 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1630 / 30
EER2 · BTU/Wh12.4–13.430 / 30
HSPF2 · BTU/Wh7.5–8.230 / 30
Cooling capacity · BTU/h28,800–30,00030 / 30
Heating capacity at 47°F / 8.3°C · BTU/h26,400–28,20030 / 30
Heating capacity at 17°F / −8.3°C · BTU/h16,800–18,30030 / 30
Heating capacity at 5°F / −15°C · BTU/h12,600–14,30030 / 30
COP at 5°F / −15°C1.92–2.1230 / 30
Equipment / loop typeHP - Split System30 / 30
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)30 / 30
Compressor stagingSingle stage30 / 30
Connected capabilityNo30 / 30

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]36BX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21571965716.007.80134001.98EPA 3647166 →
7E[C,U]36BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21571965816.007.80134001.98EPA 3647167 →
7E[C,U]36CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21832978216.007.50133001.98EPA 4584947 →
7AH1AE30PX-**AHRI reference: 21571960515.507.80127001.92EPA 3647138 →
7AH1AV30PX-**AHRI reference: 21571960815.507.80126001.94EPA 3647140 →
7AH2AE30PX-**AHRI reference: 21571961015.508.10132001.98EPA 3647142 →
7AH2AV36PXC**AHRI reference: 21571961315.508.20140002.08EPA 3647157 →
7EH30BX-**+TDR+ furnace: 80G2UH090BE12*AHRI reference: 21571968415.507.80134001.98EPA 3647175 →
7EH30BX-**+TDR+ furnace: 80G2UH090BE16*AHRI reference: 21571968515.507.80135001.96EPA 3647182 →
7EH30BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 21571968615.507.80135001.96EPA 3647183 →
7EH30BX-**+TDR+ furnace: 97G2UH045BE12*AHRI reference: 21571968715.507.80134001.94EPA 3647184 →
7EH30BX-**+TDR+ furnace: 80G1UH070BE12*AHRI reference: 21571968915.507.80134001.96EPA 3647186 →
7EH30BX-**+TDR+ furnace: 80G1UH070BE12L*AHRI reference: 21571969015.507.80134001.96EPA 3647187 →
7EH30BX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21571969115.507.80135001.98EPA 3647188 →
7EH30BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21571969215.507.80135001.98EPA 3647189 →
7AH2AE36PX-**AHRI reference: 21571961115.508.20142002.08EPA 3649573 →
7EH30BX-**+TDR+ furnace: 97G2UH045BV12*AHRI reference: 21649866615.507.80135001.96EPA 3847463 →
7EH30BX-**+TDR+ furnace: 80G2UH090BV16*AHRI reference: 21677932015.507.80135001.94EPA 3992920 →
7EH30BX-**+TDR+ furnace: EFV12BCA*AHRI reference: 21761597415.507.80132001.96EPA 4481495 →
7AH1RE36DX-**AHRI reference: 21835022915.508.10136001.99EPA 4586550 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →