ALLIED / AIR-SOURCE HEAT PUMP

7HP14F24P-**A

7HP14F SERIES · 7HP14F Series · source records, page 2

118 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 118 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16118 / 118
EER2 · BTU/Wh12–13.8118 / 118
HSPF2 · BTU/Wh7.8–8.2118 / 118
Cooling capacity · BTU/h22,800–24,000118 / 118
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,000118 / 118
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,700118 / 118
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600118 / 118
COP at 5°F / −15°C1.96–2.2118 / 118
Equipment / loop typeHP - Split System118 / 118
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)118 / 118
Compressor stagingSingle stage118 / 118
Connected capabilityNo118 / 118

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]30AX-**+TDR+ furnace: 80G2UH045AE12*AHRI reference: 21571072715.508.00112002.16EPA 3646434
7E[C,U]24BX-**+TDR+ furnace: 80G2UH090BE16*AHRI reference: 21571071215.508.00109002.04EPA 3646452
7E[C,U]24BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 21571071315.508.00109002.06EPA 3646453
7E[C,U]24BX-**+TDR+ furnace: 80G1UH070BE12*AHRI reference: 21571071615.507.80108002.04EPA 3646458
7E[C,U]24BX-**+TDR+ furnace: 80G1UH070BE12L*AHRI reference: 21571071715.507.80108002.04EPA 3646459
7E[C,U]24BX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21571071815.508.00108002.04EPA 3646460
7E[C,U]24BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21571071915.508.00108002.04EPA 3646461
7E[C,U]24BX-**+TDR+ furnace: 92G1UH030BE12*AHRI reference: 21571072015.507.80106002.00EPA 3646462
7EH30BX-**+TDR+ furnace: 80G1UH070BE12*AHRI reference: 21571079415.508.00109002.08EPA 3646464
7EH30BX-**+TDR+ furnace: 80G1UH070BE12L*AHRI reference: 21571079515.508.00109002.08EPA 3646465
7EH30BX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21571079615.508.10110002.10EPA 3646466
7EH30BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21571079715.508.10110002.10EPA 3646467
7EH30BX-**+TDR+ furnace: 92G1UH030BE12*AHRI reference: 21571079815.507.80108002.06EPA 3646468
7EH30BX-**+TDR+ furnace: 92G1UH070BE12*AHRI reference: 21571080015.508.00111002.06EPA 3646470
7E[C,U]30BX-**+TDR+ furnace: 80G2UH090BE16*AHRI reference: 21571073815.508.10114002.16EPA 3646494
7E[C,U]30AX-**+TDR+ furnace: 80G1UH045AE12L*AHRI reference: 21571073115.507.80112002.14EPA 3646505
7E[C,U]30BX-**+TDR+ furnace: 80G2UH090BE12*AHRI reference: 21571073715.507.80111002.12EPA 3646507
7EH24BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21571077115.508.10107002.02EPA 3646508
7EH30AX-**+TDR+ furnace: 80G2UH045AE12*AHRI reference: 21571077915.507.80109002.04EPA 3646524
7E[C,U]30AX-**+TDR+ furnace: 80G1UH045AE12*AHRI reference: 21571073015.507.80112002.14EPA 3646862

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →