4HP18V36P
4HP18V SERIES · source records, page 5
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4HP18V36P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 192 / 192 |
| EER2 · BTU/Wh | 11–12.3 | 192 / 192 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 192 / 192 |
| Cooling capacity · BTU/h | 22,000–34,800 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,000–34,800 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,900–24,800 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 14,100–20,000 | 192 / 192 |
| COP at 5°F / −15°C | 1.78–2.18 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | No | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EAC4X24B+ furnace: 92G1UH030BE12AHRI reference: 206906004 | 18.50 | 7.80 | 15000 | 1.90 | EPA 2448236 → |
EAC4X24B+ furnace: 92G1UH045BE12AHRI reference: 206906005 | 18.50 | 7.80 | 15500 | 1.91 | EPA 2448242 → |
BCE5V30MAHRI reference: 206905845 | 18.50 | 8.50 | 15200 | 1.98 | EPA 2448243 → |
EAH1P48C+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 212607756 | 18.50 | 8.50 | 18100 | 2.12 | EPA 2633507 → |
7EC24BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 214729577 | 18.50 | 7.80 | 15000 | 1.90 | EPA 3493117 → |
7EC24BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 214729578 | 18.50 | 7.80 | 15500 | 1.91 | EPA 3493118 → |
7EC24BX-0*+TDR+ furnace: 96G2UH030BE08AHRI reference: 214729583 | 18.50 | 8.10 | 14300 | 1.88 | EPA 3493122 → |
7EH30BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 214729693 | 18.50 | 8.50 | 15300 | 2.03 | EPA 3493194 → |
7EH30BX-0*+TDR+ furnace: EFV12BCAAHRI reference: 214729706 | 18.50 | 8.50 | 14900 | 2.03 | EPA 3493201 → |
7EH48CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 214729730 | 18.50 | 8.50 | 18100 | 2.12 | EPA 3493206 → |
7EC30BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 214729627 | 18.50 | 8.10 | 15100 | 1.96 | EPA 3493219 → |
7EC30BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 214729628 | 18.50 | 8.10 | 15000 | 1.97 | EPA 3493223 → |
7EC30BX-0*+TDR+ furnace: 96G2UH045BV12AHRI reference: 214729634 | 18.50 | 8.10 | 14900 | 1.96 | EPA 3493237 → |
7AH1AV18PX-0*AHRI reference: 215218979 | 18.50 | 8.50 | 15200 | 2.04 | EPA 3554717 → |
7AH1AV24PX-0*AHRI reference: 215218983 | 18.50 | 8.50 | 15400 | 1.88 | EPA 3554721 → |
7AH1AV30PX-0*AHRI reference: 215218987 | 18.50 | 8.50 | 15200 | 1.98 | EPA 3554725 → |
EAH1P48B+TDR+TXV+ furnace: 97G2UH070BV12AHRI reference: 214100230 | 18.50 | 8.50 | 18500 | 2.10 | EPA 4010631 → |
7EC24BX-0*+TDR+ furnace: 97G2UH030BE08AHRI reference: 214729588 | 18.50 | 8.10 | 14300 | 1.88 | EPA 4010653 → |
7EC24BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 214729591 | 18.50 | 7.80 | 15600 | 2.03 | EPA 4010656 → |
7EH30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 214729703 | 18.50 | 8.50 | 15200 | 2.11 | EPA 4010665 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.