4HP18V36P
4HP18V SERIES
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4HP18V36P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 192 / 192 |
| EER2 · BTU/Wh | 11–12.3 | 192 / 192 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 192 / 192 |
| Cooling capacity · BTU/h | 22,000–34,800 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,000–34,800 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,900–24,800 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 14,100–20,000 | 192 / 192 |
| COP at 5°F / −15°C | 1.78–2.18 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | No | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
E*1P23B+H4TXV01+ furnace: 96G2UH045BV12AHRI reference: 206905869 | 19.00 | 8.10 | 14300 | 1.89 | EPA 2447233 → |
E*1P23B+H4TXV01+ furnace: 96G2UH070BV12AHRI reference: 206905870 | 19.00 | 8.10 | 14300 | 1.91 | EPA 2447237 → |
EA(C,U)1P30B+H4TXV01+ furnace: 96G2UH070BV12AHRI reference: 206905943 | 19.00 | 8.10 | 14800 | 1.97 | EPA 2447280 → |
E*1P23B+H4TXV01+ furnace: 92G1UH070BE12AHRI reference: 206905863 | 19.00 | 8.10 | 14500 | 1.92 | EPA 2447293 → |
BCE5V36MAHRI reference: 206905446 | 19.00 | 8.50 | 18100 | 2.16 | EPA 2447548 → |
EAC4X24B+ furnace: 92G1UH070BE12AHRI reference: 206906006 | 19.00 | 7.80 | 15500 | 1.95 | EPA 2447588 → |
EAC4X24B+ furnace: 96G2UH070BV12AHRI reference: 206906013 | 19.00 | 7.80 | 15200 | 1.93 | EPA 2447595 → |
EAC4X24B+ furnace: 96G2UH045BV12AHRI reference: 206906012 | 19.00 | 7.80 | 15300 | 1.93 | EPA 2447601 → |
EA(C,U)1P24B+H4TXV01+ furnace: 92G1UH070BE12AHRI reference: 206905914 | 19.00 | 7.80 | 15500 | 1.95 | EPA 2447672 → |
EA(C,U)1P24B+H4TXV01+ furnace: 96G2UH070BV12AHRI reference: 206905921 | 19.00 | 7.80 | 15200 | 1.93 | EPA 2447679 → |
EA(C,U)1P24B+H4TXV01+ furnace: 96G2UH045BV12AHRI reference: 206905920 | 19.00 | 7.80 | 15300 | 1.93 | EPA 2447682 → |
EAC4X30B+ furnace: 96G2UH070BV12AHRI reference: 206906035 | 19.00 | 8.10 | 14800 | 1.97 | EPA 2447901 → |
EA(C,U)1P30B+H4TXV01+ furnace: 96G2UH030BE08AHRI reference: 209329617 | 19.00 | 8.10 | 14300 | 1.90 | EPA 2447967 → |
EAC4X30B+ furnace: 96G2UH030BE08AHRI reference: 209329630 | 19.00 | 8.10 | 14300 | 1.90 | EPA 2447969 → |
EAH1P30B+H4TXV01+ furnace: 92G1UH045BE12AHRI reference: 206906097 | 19.00 | 8.50 | 15200 | 2.03 | EPA 2448214 → |
EAH1P30B+H4TXV01+ furnace: 92G1UH070BE12AHRI reference: 206906098 | 19.00 | 8.50 | 15100 | 2.04 | EPA 2448215 → |
EAH1P30B+H4TXV01+ furnace: 96G2UH045BV12AHRI reference: 206906105 | 19.00 | 8.50 | 15000 | 2.03 | EPA 2448217 → |
EAH1P30B+H4TXV01+ furnace: 96G2UH070BV12AHRI reference: 206906106 | 19.00 | 8.50 | 14900 | 2.04 | EPA 2448227 → |
BCE7E18MAHRI reference: 206905847 | 19.00 | 8.50 | 14600 | 2.03 | EPA 2448247 → |
BCE7E30MAHRI reference: 206905849 | 19.00 | 8.50 | 15500 | 2.17 | EPA 2448260 → |