ALLIED / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 6

150 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6150 / 150
EER2 · BTU/Wh12.5–13150 / 150
HSPF2 · BTU/Wh8–8.5150 / 150
Cooling capacity · BTU/h46,000–48,000150 / 150
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000150 / 150
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,600150 / 150
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600150 / 150
COP at 5°F / −15°C2.16–2.38150 / 150
Equipment / loop typeHP - Split System150 / 150
Refrigerant / source-reported GWPR-410A (GWP:2088)150 / 150
Compressor stagingSingle stage150 / 150
Connected capabilityNo150 / 150

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P49C+TDR+TXV+ furnace: 80G1UH110CE20AHRI reference: 21032833515.208.10256002.26EPA 2459732
EA(C;U)1P60C+TDR+TXV+ furnace: 95G1UH100CE20XAHRI reference: 21032834415.208.10254002.38EPA 2459733
EAH1P51C*+TDR+TXV+ furnace: 92G1UH110CE20AHRI reference: 21173728915.208.30256002.28EPA 2462815
EAH1P48C*+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21173697415.208.10246002.16EPA 2463274
EAH1P48C*+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21173700115.208.00246002.18EPA 2463292
EAH1P48C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21173708115.208.00244002.18EPA 2463295
EAH1P48C*+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21173715315.208.00248002.18EPA 2463709
EAH1P48C*+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21173698715.208.00246002.18EPA 2467978
EAH1P51C*+TDR+TXV+ furnace: 92G1UH090CE16AHRI reference: 21173727315.208.30256002.30EPA 2468414
EAH1P51C*+TDR+TXV+ furnace: 80G1UH110CE20AHRI reference: 21173726515.208.30256002.30EPA 2468426
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CV20AHRI reference: 21173731215.208.30256002.28EPA 2468879
EAH1P60D*+TDR+TXV+ furnace: 96G1UH135DE20AHRI reference: 21173734315.208.10246002.20EPA 2469325
7EC48CX-0*+TDR+ furnace: 96G1UH110CE20AHRI reference: 21471271515.208.10242002.18EPA 3486247
7EC48CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21471271215.208.10244002.18EPA 3486395
7EC60CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21471276015.208.10252002.36EPA 3486478
7EH51CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21471267715.208.30256002.30EPA 3486491
7EH51CX-0*+TDR+ furnace: 92G1UH110CE20AHRI reference: 21471267915.208.30256002.28EPA 3486493
7EH51CX-0*+TDR+ furnace: 80G2UH110CV20AHRI reference: 21471268115.208.30256002.28EPA 3486520
7EH60DX-0*+TDR+ furnace: 97G2UH135DV20AHRI reference: 21471268215.208.10246002.18EPA 3486521
7EH60DX-0*+TDR+ furnace: 96G1UH135DE20AHRI reference: 21471268415.208.10246002.20EPA 3486522

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →