ALLIED / AIR-SOURCE HEAT PUMP

4HP17L42P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 3

66 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range7.8–8.3BTU/Wh
Cooling capacity40,000–42,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L42P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 66 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.666 / 66
EER2 · BTU/Wh12.5–1366 / 66
HSPF2 · BTU/Wh7.8–8.366 / 66
Cooling capacity · BTU/h40,000–42,00066 / 66
Heating capacity at 47°F / 8.3°C · BTU/h37,600–42,00066 / 66
Heating capacity at 17°F / −8.3°C · BTU/h25,000–27,60066 / 66
Heating capacity at 5°F / −15°C · BTU/h19,600–22,00066 / 66
COP at 5°F / −15°C2.02–2.266 / 66
Equipment / loop typeHP - Split System66 / 66
Refrigerant / source-reported GWPR-410A (GWP:2088)66 / 66
Compressor stagingSingle stage66 / 66
Connected capabilityNo66 / 66

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P49C+TDR+TXV+ furnace: 92G1UH110CE20AHRI reference: 21032843115.207.80199002.08EPA 2456161
EAC4X49C+TDR+ furnace: 96G1UH090CE16AHRI reference: 21032845015.207.80199002.08EPA 2457045
EA(C;U)1P49C+TDR+TXV+ furnace: 96G1UH090CE16AHRI reference: 21032843815.207.80199002.08EPA 2457463
EAC4X49C+TDR+ furnace: 96G1UH110CE20AHRI reference: 21032844415.207.80199002.08EPA 2458202
EAC4X49C+TDR+ furnace: 92G1UH090CE16AHRI reference: 21032844815.207.80198002.08EPA 2458209
EAC4X49C+TDR+ furnace: 92G1UH110CE20AHRI reference: 21032844315.207.80199002.08EPA 2459338
EA(C;U)1P49C+TDR+TXV+ furnace: 92G1UH090CE16AHRI reference: 21032843615.207.80198002.08EPA 2459582
EAD4X-48C+TDR+ furnace: 96G1DF110CE20AHRI reference: 21326531615.208.20220002.12EPA 2839896
7EH48CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21471256515.207.80202002.04EPA 3486451
7EH48CX-0*+TDR+ furnace: 80G1UH110CE20LAHRI reference: 21471256615.207.80202002.04EPA 3486454
7EH48CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471255715.207.80202002.04EPA 3486489
7EH48CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471255815.207.80202002.04EPA 3486490
7EC48CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471261115.207.80200002.08EPA 3486498
7EC49CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21471262715.207.80199002.06EPA 3486597
7EC48CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21471261515.207.80196002.06EPA 3486625
7EH48BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21471254715.207.80202002.02EPA 3486641
7EH48BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21471254815.207.80202002.02EPA 3486643
7EC49CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21471263015.207.80199002.06EPA 3486740
7EC49CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21471263615.207.80198002.08EPA 3486748
7ED48CX-0*+TDR+ furnace: 96G1DF110CE20AHRI reference: 21471258115.208.20220002.12EPA 3486779

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →