ALLIED / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 11

297 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 297 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8297 / 297
EER2 · BTU/Wh12.2–14297 / 297
HSPF2 · BTU/Wh7.8–8.7297 / 297
Cooling capacity · BTU/h34,800–36,000297 / 297
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000297 / 297
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800297 / 297
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200297 / 297
COP at 5°F / −15°C2.06–2.36297 / 297
Equipment / loop typeHP - Split System297 / 297
Refrigerant / source-reported GWPR-410A (GWP:2088)297 / 297
Compressor stagingSingle stage297 / 297
Connected capabilityNo297 / 297

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC50/60CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21471248616.007.80173002.12EPA 3491589 →
7EH48BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21471236916.008.00173002.18EPA 3491668 →
7EC36AX-0*+TDR+ furnace: 80G1UH045AE12LAHRI reference: 21471243216.007.80170002.12EPA 3491748 →
7EH51CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21471238716.008.10178002.16EPA 3491869 →
7AH2AE42PX-0*AHRI reference: 21486562216.008.30181002.36EPA 3553944 →
EAC4X36B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21032856915.807.80173002.10EPA 2456223 →
EAC4X36B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032857115.807.80170002.12EPA 2456239 →
EA(C;U)1P36A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032847615.807.80174002.10EPA 2456312 →
EAC4X36A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032855715.807.80174002.10EPA 2457249 →
EAC4X50/60C+TDR+ furnace: 80G2UH110CV20AHRI reference: 21032859215.807.80174002.10EPA 2457913 →
EA(C;U)1P36B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032848815.807.80170002.08EPA 2457935 →
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21032847315.807.80170002.08EPA 2458169 →
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21032847415.807.80170002.08EPA 2458179 →
EAC4X36B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032857015.807.80170002.08EPA 2458221 →
EAC4X50/60C+TDR+ furnace: 95G1UH080CE16XAHRI reference: 21032858915.807.80172002.10EPA 2458259 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G1UH100CE20XAHRI reference: 21032849915.807.80176002.12EPA 2458489 →
EA(C;U)1P36B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21032848015.807.80170002.08EPA 2458513 →
EAC4X50/60C+TDR+ furnace: 80G1UH100CE20XAHRI reference: 21032858315.807.80176002.12EPA 2458789 →
EA(C;U)1P36B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21032848715.807.80173002.10EPA 2458790 →
BCE5V36M*4XAHRI reference: 21032846715.808.10174002.20EPA 2458803 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →