ALLIED / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 4

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC36AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21471229116.008.10144002.28EPA 3486614 →
7EC36BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21471230316.008.10145002.28EPA 3486707 →
7EC36BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471230416.008.10143002.26EPA 3486708 →
7EH30BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21471221816.008.00137002.08EPA 3491695 →
7EC36BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21471230516.008.10143002.26EPA 3491822 →
7AH1AE36PX-0*AHRI reference: 21486563516.008.50132002.14EPA 3553869 →
BCE5V36M*4XAHRI reference: 21117439915.808.10134002.16EPA 2454909 →
EAC4X36A+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21032873915.808.00144002.26EPA 2455861 →
EAC4X36A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032874215.808.10144002.26EPA 2456129 →
EA(C;U)1P36A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032865015.808.10144002.26EPA 2456189 →
EAC4X36A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21032874015.808.00144002.26EPA 2456233 →
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21032864715.808.00144002.26EPA 2456236 →
BCE7E30M*4XAHRI reference: 21032861215.808.50147002.36EPA 2456282 →
EA(C;U)1P36B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21032865515.808.10143002.26EPA 2457265 →
EAC4X36B+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21032875215.808.10142002.26EPA 2457457 →
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21032861615.808.00141002.20EPA 2457906 →
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21032864815.808.00144002.26EPA 2457914 →
EAC4X30B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21032872815.808.00144002.22EPA 2458011 →
EA(C;U)1P36B+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21032866515.808.10142002.26EPA 2458187 →
EA(C;U)1P30B+TDR+TXV+ furnace: 80G2UH090BE12AHRI reference: 21032863315.808.10143002.24EPA 2458194 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →