ALLIED / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 2

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC36BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21471229816.208.10141002.28EPA 3486702
7EC36BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21471229916.208.10141002.28EPA 3486703
7EC36BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21471229716.208.10143002.30EPA 3491885
EA(C;U)1P30B+TDR+TXV+ furnace: 80G2UH090BE16LAHRI reference: 21032862516.008.00142002.22EPA 2455866
EAC4X36A+TDR+ furnace: 80G2UH045AE12AHRI reference: 21032874116.008.10143002.28EPA 2455916
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21032864516.008.10144002.28EPA 2456126
EAC4X36A+TDR+ furnace: 80G2UH070AE12AHRI reference: 21032873416.008.10143002.26EPA 2456185
EAC4X36A+TDR+ furnace: 80G1UH045AE12AHRI reference: 21032873616.008.10144002.28EPA 2456190
EAC4X36B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21032875616.008.10143002.26EPA 2456203
EAC4X36A+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21032873816.008.10144002.28EPA 2456238
EA(C;U)1P36B+TDR+TXV+ furnace: 80G1UH070BE12AHRI reference: 21032866416.008.10143002.26EPA 2456315
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21032864416.008.10144002.28EPA 2456387
EAC4X36A+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21032873516.008.10143002.26EPA 2457456
EAC4X36A+TDR+ furnace: 80G1UH070AE12AHRI reference: 21032873716.008.10144002.28EPA 2457699
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21032864616.008.10144002.28EPA 2457807
EAC4X36B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21032874816.008.10144002.28EPA 2457854
EA(C;U)1P36A+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21032864916.008.10143002.28EPA 2458206
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21032862316.008.00142002.22EPA 2458207
EAC4X30B+TDR+ furnace: 80G2UH090BE16AHRI reference: 21032871616.008.00142002.22EPA 2458495
EAC4X30B+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21032871716.008.00142002.22EPA 2458505