ALLIED / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 12

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X30B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21032873015.407.80144002.20EPA 2457701
EAC4X30B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032872315.407.80143002.18EPA 2457852
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032862915.407.80143002.18EPA 2458493
BCE5V30M*4XAHRI reference: 21032861115.408.10139002.16EPA 2459600
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21032863815.407.80144002.20EPA 2459607
EAC4X30B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032872215.407.80143002.18EPA 2459619
EAH1P36C*+TDR+TXV+ furnace: 95G1UH080CE16XAHRI reference: 21173593015.408.30145002.22EPA 2466649
EAH1P36C*+TDR+TXV+ furnace: 95G1UH100CE20XAHRI reference: 21173594015.408.50148002.24EPA 2467528
EAD4X-42B+TDR+ furnace: 96G1DF045BE12AHRI reference: 21326529215.408.60154002.30EPA 2839930
7EC30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21471227815.407.80144002.20EPA 3486088
7EC30BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 21471227915.407.80143002.18EPA 3486090
7EC30BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21471228015.407.80143002.18EPA 3486091
7ED42BX-0*+TDR+ furnace: 96G1DF045BE12AHRI reference: 21471224915.408.60154002.30EPA 3486217
7EC30BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21471226815.408.00145002.16EPA 3486499
7EC30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21471226915.407.80144002.14EPA 3486500
7EH36CX-0*+TDR+ furnace: 80G1UH100CE20XAHRI reference: 21471221915.408.30149002.22EPA 3486696
7EH36CX-0*+TDR+ furnace: 95G1UH080CE16XAHRI reference: 21471222015.408.30145002.22EPA 3486698
7EH36CX-0*+TDR+ furnace: 95G1UH100CE20XAHRI reference: 21471222115.408.50148002.24EPA 3486699
7EC30BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21471226215.407.80143002.18EPA 3491650
7AH1AC36PX-0*AHRI reference: 21486559415.408.10136002.14EPA 3553710

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →