ALLIED / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 9

257 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17257 / 257
EER2 · BTU/Wh12.5–14257 / 257
HSPF2 · BTU/Wh7.8–8.2257 / 257
Cooling capacity · BTU/h22,400–24,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700257 / 257
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500257 / 257
COP at 5°F / −15°C2–2.18257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21471210316.007.80108002.04EPA 3486115
7EC30BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21471218616.007.80104002.00EPA 3486141
7EH30AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21471207316.008.10105002.10EPA 3486291
7EH30AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21471207416.008.10105002.10EPA 3486293
7EH30AX-0*+TDR+ furnace: 80G2UH070AE12AHRI reference: 21471207616.008.10108002.12EPA 3486298
7EH30AX-0*+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21471207716.008.10108002.12EPA 3486301
7EC24BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21471214016.007.80104002.02EPA 3486312
7EC24AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21471212216.007.80106002.02EPA 3486363
7EC24AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21471212316.007.80106002.02EPA 3486364
7EC24AX-0*+TDR+ furnace: 80G2UH070AE12AHRI reference: 21471212516.007.80106002.02EPA 3486366
7EC24AX-0*+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21471212616.007.80106002.02EPA 3486367
7EC30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21471218316.007.80102002.00EPA 3486368
7EH24AX-0*+TDR+ furnace: 80G2UH070AE12AHRI reference: 21471206516.007.80105002.04EPA 3486381
7EH24AX-0*+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21471206616.007.80105002.04EPA 3486382
7EC30BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21471216916.007.80106002.00EPA 3486390
7ED30/36BX-0*+TDR+ furnace: 80G2DF090BE16AHRI reference: 21471210516.008.20112002.08EPA 3486393
7EC24BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21471214916.007.80106002.06EPA 3486416
7EH30BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21471208516.007.80108002.04EPA 3486419
7EH30BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21471208616.007.80108002.02EPA 3486420
7ED30/36BX-0*+TDR+ furnace: 80G1DF070BE12AHRI reference: 21471210916.008.10112002.10EPA 3486430

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →