ALLIED / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 9

256 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 256 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8256 / 256
EER2 · BTU/Wh12.2–14256 / 256
HSPF2 · BTU/Wh7.8–8.5256 / 256
Cooling capacity · BTU/h18,000256 / 256
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000256 / 256
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100256 / 256
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700256 / 256
COP at 5°F / −15°C1.9–2.16256 / 256
Equipment / loop typeHP - Split System256 / 256
Refrigerant / source-reported GWPR-410A (GWP:2088)256 / 256
Compressor stagingSingle stage256 / 256
Connected capabilityNo256 / 256

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21032895716.007.8075001.92EPA 2458511
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21032897216.007.8078001.96EPA 2458530
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032894416.008.0082002.08EPA 2458531
EAC4X24B+TDR+ furnace: 92G1UH030BE12AHRI reference: 21032906016.008.1084002.08EPA 2458811
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21032894216.008.0082002.06EPA 2458812
EA(C;U)1P24B+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21032894016.008.0082002.06EPA 2459067
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032893916.008.0082002.04EPA 2459139
EA(C;U)1P24B+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21032895116.008.0082002.04EPA 2459340
EAC4X24B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032905716.008.0082002.08EPA 2459616
EAH1P24A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21173429316.007.8081002.00EPA 2463228
EAH1P24B*+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21173460616.008.1082002.06EPA 2463636
EAH1P30B*+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21173479816.007.8078001.98EPA 2463643
EAH1P24B*+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21173455016.008.1084002.08EPA 2464447
EAH1P24A*+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21173431016.008.1082002.02EPA 2464466
EAH1P24B*+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21173442116.008.1082002.06EPA 2465315
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21173439416.008.1087002.04EPA 2466155
EAH1P24A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21173430316.007.8081002.00EPA 2467027
EAH1P24B*+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21173463416.008.1087002.08EPA 2467037
EAH1P24B*+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21173461716.008.1082002.06EPA 2467949
EAD4X-30/36B+TDR+ furnace: 80G1DF070BE12AHRI reference: 21326526316.008.3087002.06EPA 2839947

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →