4HP17L18P-**A
4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 12
256 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 256 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.8 | 256 / 256 |
| EER2 · BTU/Wh | 12.2–14 | 256 / 256 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 256 / 256 |
| Cooling capacity · BTU/h | 18,000 | 256 / 256 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,000–18,000 | 256 / 256 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,200–12,100 | 256 / 256 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,500–9,700 | 256 / 256 |
| COP at 5°F / −15°C | 1.9–2.16 | 256 / 256 |
| Equipment / loop type | HP - Split System | 256 / 256 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 256 / 256 |
| Compressor staging | Single stage | 256 / 256 |
| Connected capability | No | 256 / 256 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EC24AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 214711997 | 15.80 | 7.80 | 8000 | 2.04 | EPA 3486571 → |
7EC24AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 214711998 | 15.80 | 7.80 | 8000 | 2.04 | EPA 3486573 → |
EAC4X24B+TDR+ furnace: 96G1UH030BE08AHRI reference: 210329061 | 15.60 | 8.00 | 8400 | 2.06 | EPA 2457294 → |
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 210328948 | 15.60 | 8.00 | 8400 | 2.06 | EPA 2457746 → |
BCE7E18M*4XAHRI reference: 210328928 | 15.60 | 8.50 | 8200 | 2.16 | EPA 2459391 → |
BCE5V24M*4XAHRI reference: 211174380 | 15.60 | 8.10 | 8400 | 2.12 | EPA 2459924 → |
EAH1P30B*+TDR+TXV+ furnace: 80G2UH090BE16AHRI reference: 211734686 | 15.60 | 7.80 | 8000 | 1.92 | EPA 2464065 → |
EAH1P30B*+TDR+TXV+ furnace: 80G2UH090BE16LAHRI reference: 211734694 | 15.60 | 7.80 | 8000 | 1.92 | EPA 2465712 → |
EAH1P24B*+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 211734592 | 15.60 | 8.10 | 8400 | 2.06 | EPA 2465723 → |
EAH1P30B*+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 211734753 | 15.60 | 7.80 | 8000 | 1.92 | EPA 2466601 → |
7EH24BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 214711957 | 15.60 | 8.10 | 8400 | 2.06 | EPA 3486021 → |
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 214711966 | 15.60 | 7.80 | 8000 | 1.92 | EPA 3486190 → |
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 214711967 | 15.60 | 7.80 | 8000 | 1.92 | EPA 3486254 → |
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 214711974 | 15.60 | 7.80 | 8000 | 1.92 | EPA 3486476 → |
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 214711975 | 15.60 | 7.80 | 8000 | 1.92 | EPA 3486477 → |
7EC24BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 214712024 | 15.60 | 8.00 | 8400 | 2.06 | EPA 3486657 → |
7AH1AV24PX-0*AHRI reference: 214865592 | 15.60 | 8.10 | 8400 | 2.12 | EPA 3553709 → |
7AH2AE18PX-0*AHRI reference: 214865552 | 15.50 | 8.10 | 8200 | 2.16 | EPA 3553850 → |
BCE5C24M*4XAHRI reference: 211174371 | 15.40 | 8.10 | 8500 | 2.10 | EPA 2459911 → |
BCE5C24M*1P+TXVAHRI reference: 212285482 | 15.40 | 8.10 | 8500 | 2.10 | EPA 2468044 → |