Airquest / AIR-SOURCE HEAT PUMP

R5H5S24*K*AAA*

15 SEER2 HP · source records, page 9

190 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for R5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 190 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5190 / 190
EER2 · BTU/Wh11.7–13190 / 190
HSPF2 · BTU/Wh7.8–8.5190 / 190
Cooling capacity · BTU/h22,200–24,400190 / 190
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000190 / 190
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200190 / 190
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900190 / 190
COP at 5°F / −15°C1.96–2.26190 / 190
Equipment / loop typeHP - Split System190 / 190
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)190 / 190
Compressor stagingSingle stage190 / 190
Connected capabilityNo190 / 190

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M17A*+ furnace: *96VTN0801716B*AHRI reference: 21420126915.207.80114002.08EPA 3406502
EA*5X37M17A*+ furnace: *80VTL0701716B*AHRI reference: 21420037115.207.80113002.08EPA 3406676
EA*5X37M17A*+ furnace: *80VTL0451412B*AHRI reference: 21420032915.207.80112002.08EPA 3406732
EA*5X37M17A*+ furnace: *80MS(N,L)0451412A*AHRI reference: 21419970415.207.80113002.08EPA 3407185
EA*5X37M21A*+ furnace: *96VTN0601716B*AHRI reference: 21420316815.207.80118002.12EPA 3407450
EA*5X37M21A*+ furnace: *96VTN0801716B*AHRI reference: 21420319915.207.80116002.12EPA 3407481
EA*5X37M17A*+ furnace: *92MSN0601412A*AHRI reference: 21420066915.207.80113002.08EPA 3407573
EA*5X37M17A*+ furnace: *96MSN0601716A*AHRI reference: 21420079315.207.80114002.08EPA 3407625
EA*5X37M17A*+ furnace: *80VSL0451412B*AHRI reference: 21419994015.207.80112002.08EPA 3407923
EA*5X37M21A*+ furnace: *96MSN0601716A*AHRI reference: 21420248215.207.80117002.12EPA 3407953
EA*5X37M21A*+ furnace: *96MSN0801716A*AHRI reference: 21420251415.207.80116002.12EPA 3407989
EA*5X37M17A*+ furnace: *80VSL0701412B*AHRI reference: 21419996515.207.80112002.08EPA 3408014
EA*5X37M17A*+ furnace: *80VSL0701716B*AHRI reference: 21419999015.207.80113002.08EPA 3408038
EA*5X37M21A*+ furnace: *80VSL0701716B*AHRI reference: 21420166315.207.80115002.14EPA 3408189
EA*5X37M17A*+ furnace: *96VSN0601716B*AHRI reference: 21420091015.207.80114002.08EPA 3408324
EA*5X37M17A*+ furnace: *96VSN0801716B*AHRI reference: 21420093515.207.80114002.08EPA 3408350
EA*5X37M21A*+ furnace: *80VSL0901716B*AHRI reference: 21420168915.207.80116002.14EPA 3408386
EA*5X37M21A*+ furnace: *96VSN0801716B*AHRI reference: 21420273115.207.80116002.12EPA 3408700
EA*5X37M21A*+ furnace: *96VSN0601716B*AHRI reference: 21420270615.207.80118002.12EPA 3408833
EA*5X25M17A*+ furnace: *80CSU0401712A*AHRI reference: 21421028915.207.80112002.12EPA 3409653

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →