Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X48M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217955770 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4565282 → |
EA*5X60M24A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 217955782 | 15.50 | 9.00 | 37000 | 2.10 | EPA 4565292 → |
EA*5X60M24A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217955794 | 15.50 | 9.00 | 37600 | 2.08 | EPA 4565304 → |
EVM5X61M24A*+TDRCold climate designationAHRI reference: 217955146 | 15.50 | 9.50 | 40000 | 2.24 | EPA 4565338 → |
EVD5X61M24A*+TDRCold climate designationAHRI reference: 217955160 | 15.50 | 9.50 | 40000 | 2.24 | EPA 4565351 → |
EVM5X48M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217955162 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4565354 → |
EVM5X48M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217955164 | 15.50 | 9.00 | 39500 | 2.10 | EPA 4565355 → |
EVM5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217955168 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4565357 → |
EVM5X48M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217955172 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4565361 → |
EVM5X48M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217955176 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4565365 → |
EVM5X48M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217955182 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4565369 → |
EVM5X48M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217955184 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4565371 → |
EVM5X48M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217955190 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4565375 → |
EVM5X48M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217955192 | 15.50 | 9.00 | 40500 | 2.10 | EPA 4565377 → |
EA*5X48M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217955760 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4565384 → |
EA*5X61M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217955910 | 15.50 | 9.00 | 37400 | 2.10 | EPA 4565414 → |
EA*5X61M21A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217955922 | 15.50 | 9.00 | 37600 | 2.10 | EPA 4565426 → |
EA*5X48M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217955704 | 15.50 | 9.00 | 37400 | 2.08 | EPA 4565428 → |
EA*5X48M21A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217955718 | 15.50 | 9.00 | 37200 | 2.08 | EPA 4565443 → |
EA*5X48M21A*+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 217955724 | 15.50 | 9.00 | 37400 | 2.08 | EPA 4565448 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.