Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 9
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X32M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217938131 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4551701 → |
EVD5X31M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217940948 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4551717 → |
EVD5X31M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217940963 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4551732 → |
EVM5X36M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217938358 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4551747 → |
EVD5X30M17A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217940327 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4551784 → |
EVD5X31M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217940978 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4551802 → |
EVD5X31M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217940993 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4551818 → |
EVD5X25M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217939977 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4551869 → |
EVM5X36M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217938676 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4551981 → |
EVM5X36M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217938326 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4552016 → |
EVD5X36M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217942724 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4552161 → |
EVD5X36M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217941630 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4552200 → |
EVD5X37M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217942979 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4552236 → |
EVD5X37M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217943130 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4552253 → |
EVD5X37M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217943145 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4552264 → |
EVD5X30M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217940750 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4552313 → |
EVM5X25M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217936148 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4552360 → |
EVD5X36M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217942754 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4552502 → |
EVD5X37M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217942889 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4552506 → |
EVM5X25M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217935906 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4552523 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →