Airquest / AIR-SOURCE HEAT PUMP

Q5H9V24*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 47

1,093 published source records · source checked Sep 21, 2026

SEER2 range15.2–19.5BTU/Wh
HSPF2 range8–10BTU/Wh
Cooling capacity22,200–25,400BTU/h

Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19.51,093 / 1,093
EER2 · BTU/Wh11.5–141,093 / 1,093
HSPF2 · BTU/Wh8–101,093 / 1,093
Cooling capacity · BTU/h22,200–25,4001,093 / 1,093
Heating capacity at 47°F / 8.3°C · BTU/h22,400–25,8001,093 / 1,093
Heating capacity at 17°F / −8.3°C · BTU/h19,800–25,2001,093 / 1,093
Heating capacity at 5°F / −15°C · BTU/h20,000–22,2001,093 / 1,093
COP at 5°F / −15°C1.74–2.021,093 / 1,093
Equipment / loop typeHP - Split System1,093 / 1,093
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)1,093 / 1,093
Compressor stagingContinuously variable1,093 / 1,093
Connected capabilityNo1,093 / 1,093

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X24M12A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21794535316.509.50212001.92EPA 4560720 →
ESH5X24M12A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 21794833216.509.00212001.85EPA 4560788 →
ESH5X24M12A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 21794834716.509.00214001.80EPA 4560804 →
ESH5X30M12A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 21794578916.509.50214001.92EPA 4560934 →
ESH5X30M12A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 21794580416.509.50214001.92EPA 4560951 →
ESH5X30M12A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 21794581916.509.50214001.92EPA 4560967 →
ESH5X36M12A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21794583416.509.50212001.92EPA 4560985 →
EA*5X24M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 21794702316.509.50214001.92EPA 4561110 →
ESH5X24M12A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 21794885816.509.00214001.85EPA 4561412 →
ESH5X30M12A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 21794679616.509.50214001.92EPA 4561692 →
ESH5X30M12A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 21794577416.509.50214001.92EPA 4562187 →
ESH5X36M12A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21794587916.509.50212001.92EPA 4562285 →
ESH5X36M12A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21794584916.509.50212001.92EPA 4562390 →
ESH5X36M12A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21794586416.509.50212001.92EPA 4562405 →
EA*5X30M14A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 21794610516.509.00212001.80EPA 4562570 →
ESH5X30M12A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 21794621116.509.50212001.92EPA 4562583 →
ESH5X24M12A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 21794613516.509.00214001.85EPA 4562597 →
ESH5X24M12A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21794615016.509.00214001.85EPA 4562612 →
ESH5X36M12A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21794891816.509.50212001.94EPA 4562623 →
ESH5X30M12A*+ furnace: *80VSL1352422B*Cold climate designationAHRI reference: 21794783416.509.00214001.85EPA 4562919 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →