Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 13
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X25M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217939660 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554241 → |
EVD5X25M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217939675 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554256 → |
EVD5X25M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217939690 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554271 → |
EVD5X30M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217940705 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554308 → |
EVD5X30M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217940720 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554323 → |
EVM5X30M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217936481 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554402 → |
EVM5X30M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217936496 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554419 → |
EVM5X30M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217936511 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554426 → |
EVD5X36M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217942181 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4554439 → |
EVD5X36M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217942120 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4554459 → |
EVD5X30M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217940675 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4554525 → |
EVD5X36M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217942135 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4554532 → |
EVD5X36M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217942150 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554546 → |
EVD5X25M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217939705 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4554573 → |
EVM5X25M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217936361 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4554589 → |
EVD5X38M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217944147 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4554600 → |
EVD5X36M21A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217942541 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4554612 → |
EVD5X36M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217942570 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4554628 → |
EVD5X38M17A*+ furnace: OLV098A12*Cold climate designationAHRI reference: 217944421 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4554654 → |
EVD5X38M17A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 217944436 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4554669 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →