Airquest / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP · source records, page 5

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M24A*+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21793259016.009.00410002.14EPA 4544834
EA*5X61M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21793260516.009.00410002.14EPA 4544850
EA*5X60M24A*+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21793181016.009.00405002.12EPA 4545026
EA*5X61M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21793220016.008.50410002.00EPA 4545073
EA*5X60M24A*+ furnace: *80MSU1002120A*AHRI reference: 21793155416.008.50400002.00EPA 4545297
EA*5X60M24A*+ furnace: *80CTL0902120B*AHRI reference: 21793156916.009.00405002.12EPA 4545311
EA*5X60M24A*+ furnace: *80CTL1102120B*AHRI reference: 21793158416.009.00405002.12EPA 4545326
F5MA5*60L*D*AHRI reference: 21793335716.009.00400002.16EPA 4545350
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 21793262016.009.00405002.14EPA 4545516
EA*5X61M24A*+ furnace: *95CSU1002122B*AHRI reference: 21793263616.008.50405002.05EPA 4545533
EA*5X61M24A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21793266616.009.00410002.14EPA 4545563
EA*5X61M24A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21793284616.009.00410002.14EPA 4545677
EA*5X61M24A*+ furnace: *97CTN1202422A*AHRI reference: 21793286116.009.00405002.14EPA 4545682
EA*5X60M24A*+ furnace: *80CTL1352422B*AHRI reference: 21793159916.009.00405002.12EPA 4545695
EA*5X60M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21793161416.009.00405002.12EPA 4545710
EA*5X61M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21793289116.009.00410002.14EPA 4545737
EA*5X61M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21793295116.009.00410002.14EPA 4545845
EA*5X61M24A*+ furnace: *96VTN1002122B*AHRI reference: 21793290616.009.00405002.14EPA 4545854
EA*5X61M24A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 21793292116.009.00410002.14EPA 4545870
EA*5X61M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21793223016.008.50410002.05EPA 4545973

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →