Airquest / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP · source records, page 2

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21792097516.008.00405001.96EPA 4537974
EVM5X60M21A*+ furnace: *80CSU0802120B*AHRI reference: 21791843116.008.00395001.96EPA 4538467
EVM5X61M24A*+ furnace: *96VTN1002122B*AHRI reference: 21791983116.008.00405001.96EPA 4538634
EVD5X61M24A*+ furnace: *96VTN1002122B*AHRI reference: 21792180316.008.00410001.96EPA 4539067
EVD5X61M24A*+ furnace: *97VTN1002122A*AHRI reference: 21792183316.008.00410001.96EPA 4539083
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21792038816.008.00395001.96EPA 4539107
EVD5X60M21A*+ furnace: *97VTN1002122A*AHRI reference: 21792043316.008.00395001.96EPA 4539127
EVD5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21792130616.008.00400001.96EPA 4539195
EVD5X61M21A*+ furnace: *80CSU0802120B*AHRI reference: 21792088516.008.00405001.96EPA 4539265
EVD5X61M21A*+ furnace: *97VTN1002122A*AHRI reference: 21792135116.008.00400001.96EPA 4539713
EVD5X60M21A*+ furnace: *80VSL1102122B*AHRI reference: 21792001216.008.00395001.96EPA 4539754
EVM5X60M21A*+ furnace: *80VSL1102122B*AHRI reference: 21791847616.008.00390001.96EPA 4540268
EVM5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21791849116.008.00390001.94EPA 4540280
EVD5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21792091516.008.00400001.96EPA 4540347
EVD5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 21792093016.008.00400001.96EPA 4540387
EVD5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21792004216.008.00395001.96EPA 4540458
EVD5X60M21A*+ furnace: *80CTL0902120B*AHRI reference: 21792008716.008.00395001.94EPA 4540486
EVD5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21792144116.008.00410001.96EPA 4540523
EVM5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21791879116.008.00395001.96EPA 4540653
EVM5X60M21A*+ furnace: *96CTN1002122B*AHRI reference: 21791882116.008.00395001.94EPA 4540696