Airquest / AIR-SOURCE HEAT PUMP

N5H9V48*K*AAA*

Performance 19 SEER2 VS HP · source records, page 23

507 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity43,500–49,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19507 / 507
EER2 · BTU/Wh10–13.5507 / 507
HSPF2 · BTU/Wh8.5–10507 / 507
Cooling capacity · BTU/h43,500–49,500507 / 507
Heating capacity at 47°F / 8.3°C · BTU/h46,500–55,000507 / 507
Heating capacity at 17°F / −8.3°C · BTU/h38,500–47,000507 / 507
Heating capacity at 5°F / −15°C · BTU/h36,000–41,500507 / 507
COP at 5°F / −15°C1.95–2.32507 / 507
Equipment / loop typeHP - Split System507 / 507
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)507 / 507
Compressor stagingContinuously variable507 / 507
Connected capabilityNo507 / 507

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M24A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21795296115.509.00376002.08EPA 4560338 →
ESH5X48M12A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21795312915.508.50368002.00EPA 4560487 →
EA*5X48M21A*+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21795259515.509.00374002.08EPA 4561201 →
EA*5X48M21A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21795260915.509.00372002.08EPA 4561215 →
EVD5X61M24A*+TDRCold climate designationAHRI reference: 21795462015.509.50400002.24EPA 4562135 →
EA*5X60M24A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21795273715.509.00374002.08EPA 4562830 →
EA*5X48M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 21795269515.509.00372002.08EPA 4562835 →
EA*5X48M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 21795270915.509.00372002.08EPA 4562851 →
EA*5X60M24A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21795272315.509.00376002.08EPA 4562865 →
EA*5X48M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21795255315.509.00374002.08EPA 4563491 →
EA*5X48M21A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21795256715.509.00372002.08EPA 4563505 →
EVM5X61M24A*+TDRCold climate designationAHRI reference: 21795452215.509.50400002.24EPA 4563534 →
EVM5X48M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21791516115.209.00400002.12EPA 4530427 →
EVM5X48M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21791523915.209.00405002.10EPA 4531028 →
EVM5X48M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21791525215.209.00400002.12EPA 4531354 →
EVM5X48M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21791530515.209.00400002.10EPA 4532079 →
EVM5X48M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21791534415.209.00400002.10EPA 4532443 →
EVD5X49M24A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21791673915.209.00410002.12EPA 4532745 →
EVM5X48M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21791526515.209.00405002.10EPA 4535512 →
EVM5X48M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21791527815.209.00400002.12EPA 4535526 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →