N5H9V48*K*AAA*
Performance 19 SEER2 VS HP · source records, page 18
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X48M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217914953 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4533143 → |
EVM5X48M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217914966 | 15.50 | 9.00 | 39500 | 2.10 | EPA 4533153 → |
EVM5X49M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217915539 | 15.50 | 9.00 | 40000 | 2.15 | EPA 4533263 → |
EVD5X49M24A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 217916856 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4533413 → |
EVM5X60M21A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217915956 | 15.50 | 9.00 | 41000 | 2.12 | EPA 4533526 → |
EVM5X60M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 217916047 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4533543 → |
EVM5X48M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217915096 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4533826 → |
EVM5X48M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217915135 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4533867 → |
EVM5X60M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217916152 | 15.50 | 9.50 | 40500 | 2.24 | EPA 4534297 → |
EVM5X49M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 217915617 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4534650 → |
EVM5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217914992 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4535095 → |
EVM5X48M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217915018 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4535119 → |
EVM5X49M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 217915656 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4535197 → |
EVM5X49M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217915682 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4535222 → |
EVM5X48M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217915291 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4535555 → |
EVM5X60M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217915787 | 15.50 | 9.00 | 40000 | 2.10 | EPA 4535722 → |
EVD5X49M24A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 217916778 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4536090 → |
EVD5X49M24A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217916791 | 15.50 | 9.00 | 40500 | 2.10 | EPA 4536103 → |
EVD5X49M24A*+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 217916830 | 15.50 | 9.00 | 40500 | 2.12 | EPA 4536130 → |
EVM5X49M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217915461 | 15.50 | 9.00 | 41000 | 2.10 | EPA 4536248 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.