N5H9V36*K*AAA*
Performance 19 SEER2 VS HP · source records, page 3
450 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X43M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217909511 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4532151 → |
EVM5X43M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217909526 | 16.00 | 8.50 | 24600 | 2.05 | EPA 4532166 → |
EVM5X43M21A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217909496 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4532293 → |
EVM5X43M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217910128 | 16.00 | 8.50 | 25200 | 2.05 | EPA 4532330 → |
EVM5X43M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217910144 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4532347 → |
EVM5X43M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217909541 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4532497 → |
EVM5X43M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217909556 | 16.00 | 8.50 | 24600 | 2.05 | EPA 4532516 → |
EVD5X42M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217913169 | 16.00 | 8.50 | 26000 | 2.00 | EPA 4532582 → |
EVM5X43M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217909586 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4532880 → |
EVD5X38M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217912820 | 16.00 | 9.00 | 26200 | 2.14 | EPA 4533015 → |
EVM5X43M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217910159 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4533054 → |
EVM5X43M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217910175 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4533069 → |
EVM5X43M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217910190 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4533084 → |
EVM5X43M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217910205 | 16.00 | 8.50 | 25200 | 2.05 | EPA 4533100 → |
EVD5X37M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217912595 | 16.00 | 9.00 | 26200 | 2.12 | EPA 4533163 → |
EVM5X43M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217909661 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4533431 → |
EVM5X43M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217909676 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4533446 → |
EVM5X43M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217909692 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4533462 → |
EVM5X48M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217910475 | 16.00 | 9.00 | 26000 | 2.14 | EPA 4533724 → |
EVM5X48M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217910445 | 16.00 | 9.00 | 26200 | 2.14 | EPA 4533787 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →