N5H9V36*K*AAA*
Performance 19 SEER2 VS HP · source records, page 19
450 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X49M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217910869 | 15.20 | 8.50 | 26600 | 2.00 | EPA 4535176 → |
EVD5X42M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217913443 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4535256 → |
EVM5X36M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217909102 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535600 → |
EVM5X36M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217909132 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535616 → |
EVD5X42M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217913804 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535631 → |
EVD5X38M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217913034 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4535685 → |
EVD5X38M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217913064 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4535716 → |
EVM5X48M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217910671 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4535837 → |
EVD5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217911157 | 15.20 | 8.50 | 25600 | 2.02 | EPA 4535863 → |
EVD5X36M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217911461 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535918 → |
EVD5X36M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217911491 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535934 → |
EVD5X42M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217913245 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4535952 → |
EVD5X42M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217913261 | 15.20 | 8.50 | 26000 | 2.00 | EPA 4535966 → |
EVD5X42M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217913276 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4536036 → |
EVD5X36M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217911339 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4536055 → |
EVD5X36M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217911369 | 15.20 | 8.50 | 26000 | 2.00 | EPA 4536072 → |
EVD5X36M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217911384 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4536083 → |
EA*5X42M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217924022 | 15.20 | 9.00 | 25600 | 2.08 | EPA 4536399 → |
EA*5X42M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217923962 | 15.20 | 8.50 | 25600 | 1.95 | EPA 4536479 → |
EA*5X43M21A*+ furnace: *95MSU0802120A*AHRI reference: 217925074 | 15.20 | 9.00 | 24800 | 2.08 | EPA 4536550 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.