N5H9V36*K*AAA*
Performance 19 SEER2 VS HP · source records, page 15
450 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X42M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217913593 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4530835 → |
EVD5X42M21A*+ furnace: *80VSL0902120B*AHRI reference: 217913578 | 15.20 | 8.00 | 26200 | 2.08 | EPA 4530889 → |
EVM5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217908950 | 15.20 | 8.50 | 25600 | 2.02 | EPA 4530989 → |
EVD5X38M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217913003 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531115 → |
EVM5X49M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217911067 | 15.20 | 8.50 | 26600 | 2.02 | EPA 4531155 → |
EVD5X38M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217912957 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531161 → |
EVD5X38M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217912972 | 15.20 | 8.50 | 26200 | 2.00 | EPA 4531174 → |
EVM5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217910535 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531370 → |
EVM5X36M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217909025 | 15.20 | 8.50 | 25800 | 2.04 | EPA 4531397 → |
EVD5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217914197 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531507 → |
EVD5X48M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217914347 | 15.20 | 8.50 | 26600 | 2.00 | EPA 4531544 → |
EVD5X36M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217912094 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531673 → |
EVD5X36M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217912110 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531689 → |
EVD5X48M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217914302 | 15.20 | 8.50 | 26400 | 2.00 | EPA 4531755 → |
EVD5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217914317 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531769 → |
EVD5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217912655 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531821 → |
EVD5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217912640 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531839 → |
EVD5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217912564 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4531859 → |
EVD5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217912580 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4531878 → |
EVD5X42M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217913124 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4531901 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →