N5H8T60*K*AAA*
2-STAGE 18 SEER HP
122 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–17.5 | 122 / 122 |
| EER2 · BTU/Wh | 11.7–13 | 122 / 122 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 122 / 122 |
| Cooling capacity · BTU/h | 54,000–58,000 | 122 / 122 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–61,500 | 122 / 122 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 36,200–38,500 | 122 / 122 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,600–31,800 | 122 / 122 |
| COP at 5°F / −15°C | 2.1–2.34 | 122 / 122 |
| Equipment / loop type | HP - Split System | 122 / 122 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 122 / 122 |
| Compressor staging | Two-stage | 122 / 122 |
| Connected capability | No | 122 / 122 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B60L0D*AHRI reference: 215560746 | 17.50 | 8.10 | 30200 | 2.30 | EPA 3982834 → |
QFVA5D6021X*AHRI reference: 218695464 | 17.50 | 8.10 | 31400 | 2.34 | EPA 4683363 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 215629094 | 16.50 | 8.00 | 29600 | 2.30 | EPA 3951009 → |
EA*5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 215629893 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951139 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 215629971 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951202 → |
EA*5X61M24A*+ furnace: *80CSU0802120A*AHRI reference: 215629984 | 16.50 | 7.80 | 31400 | 2.22 | EPA 3951243 → |
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 215630025 | 16.50 | 8.10 | 29800 | 2.14 | EPA 3951388 → |
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 215630038 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951401 → |
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 215630054 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951415 → |
EA*5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 215630073 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951435 → |
EA*5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 215629580 | 16.50 | 8.10 | 30000 | 2.12 | EPA 3951537 → |
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 215629615 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951569 → |
EA*5X61M24A*+ furnace: *80CTL0902120B*AHRI reference: 215630103 | 16.50 | 8.10 | 30200 | 2.26 | EPA 3951607 → |
EA*5X61M24A*+ furnace: *80CTL1102120B*AHRI reference: 215630117 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951621 → |
EA*5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 215630131 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951639 → |
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 215630164 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951673 → |
EA*5X61M24A*+ furnace: *95CSU1002122B*AHRI reference: 215630201 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951709 → |
EA*5X61M24A*+ furnace: *97CMN1002122B*AHRI reference: 215630243 | 16.50 | 8.10 | 30400 | 2.12 | EPA 3951733 → |
EA*5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 215629692 | 16.50 | 8.00 | 30400 | 2.25 | EPA 3951763 → |
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 215629725 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951794 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →