Airquest / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 10

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 21562498816.508.10246002.14EPA 3949131
EVD5X60M21A*+ furnace: *80CTL0702120B*AHRI reference: 21562478716.508.10256002.06EPA 3949194
EVD5X61M21A*+ furnace: *80CTL0702120B*AHRI reference: 21562509916.508.10256002.08EPA 3949311
EVD5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 21562562616.508.10252002.12EPA 3949401
EVD5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21562526016.508.10252002.10EPA 3949559
EVD5X61M24A*+ furnace: *95CSU0802120B*AHRI reference: 21562552816.508.10256002.08EPA 3949649
EVD5X61M24A*+ furnace: *97CMN1202422B*AHRI reference: 21562557016.508.10252002.12EPA 3949675
EVD5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 21562544416.508.10256002.10EPA 3949781
EVD5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 21562567516.508.10256002.10EPA 3950004
EVD5X61M24A*+ furnace: *96VTN1202422B*AHRI reference: 21562577116.508.10252002.12EPA 3950165
EVD5X61M21A*+TDRAHRI reference: 21562870116.508.10242002.16EPA 3950474
EVD5X61M24A*+TDRAHRI reference: 21562872016.508.10242002.16EPA 3950492
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562883116.508.10252002.24EPA 3950510
EVD5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21562884416.508.10242002.14EPA 3950521
EVD5X60M21A*+TDRAHRI reference: 21562866316.508.00240002.15EPA 3950636
EVM5X49M21A*+TDRAHRI reference: 21562853016.508.00240002.15EPA 3950769
EVM5X60M21A*+TDRAHRI reference: 21562854916.508.00240002.15EPA 3950789
EVM5X61M24A*+TDRAHRI reference: 21562858716.508.10242002.16EPA 3950827
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 21563186116.508.10256002.20EPA 3952576
EA*5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 21563247216.508.10254002.22EPA 3952769

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →