N5H8T48*K*AAA*
2-STAGE 18 SEER HP
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11.7–13.5 | 407 / 407 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 45,500–50,500 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 407 / 407 |
| COP at 5°F / −15°C | 2.06–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B60L0D*AHRI reference: 215560720 | 18.00 | 8.10 | 24600 | 2.32 | EPA 3982804 → |
QFVA5D6021X*AHRI reference: 218695447 | 18.00 | 8.50 | 25800 | 2.32 | EPA 4683380 → |
EVM5X49M21A*+ furnace: *80MSU0802120A*AHRI reference: 215623317 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3947643 → |
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 215624038 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3948046 → |
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 215623715 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3948275 → |
EVD5X49M24A*+ furnace: *80MSU0802120A*AHRI reference: 215624473 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3948713 → |
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 215625003 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3949143 → |
EVD5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 215625029 | 17.50 | 8.50 | 24800 | 2.26 | EPA 3949242 → |
EVD5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 215625045 | 17.50 | 8.10 | 25000 | 2.12 | EPA 3949258 → |
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 215625064 | 17.50 | 8.50 | 24400 | 2.30 | EPA 3949276 → |
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 215625083 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949295 → |
EVD5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 215625113 | 17.50 | 8.50 | 25200 | 2.24 | EPA 3949325 → |
EVD5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 215625127 | 17.50 | 8.50 | 25000 | 2.24 | EPA 3949340 → |
EVD5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 215625412 | 17.50 | 8.50 | 25200 | 2.24 | EPA 3949357 → |
EVD5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 215625661 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949437 → |
EVD5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 215625160 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3949460 → |
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 215625295 | 17.50 | 8.10 | 24400 | 2.16 | EPA 3949595 → |
EVD5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 215625373 | 17.50 | 8.50 | 24600 | 2.28 | EPA 3949744 → |
EVD5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 215625399 | 17.50 | 8.50 | 25000 | 2.24 | EPA 3949769 → |
EVD5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 215625472 | 17.50 | 8.50 | 24800 | 2.28 | EPA 3949805 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →