Airquest / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 9

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X30M14A*+ furnace: *80CTL0701412B*AHRI reference: 21564520917.008.10108002.06EPA 3958332
EA*5X30M14A*+ furnace: *80VTL0451412B*AHRI reference: 21564523517.008.10109002.06EPA 3958353
EA*5X30M17A*+ furnace: *80CSU0401712A*AHRI reference: 21564538817.007.80110002.06EPA 3958440
EA*5X30M17A*+ furnace: *80VSL0451412B*AHRI reference: 21564540917.008.10109002.06EPA 3958446
EA*5X30M17A*+ furnace: *80VSL0701412B*AHRI reference: 21564542917.008.10109002.06EPA 3958467
EA*5X30M17A*+ furnace: *80VSL0701716B*AHRI reference: 21564544917.008.10110002.06EPA 3958476
EA*5X30M17A*+ furnace: *80VSL0901716B*AHRI reference: 21564547017.008.10110002.04EPA 3958487
EA*5X30M17A*+ furnace: *80MSU0401712A*AHRI reference: 21564549417.007.80108002.06EPA 3958505
EA*5X30M17A*+ furnace: *80CTL0701412B*AHRI reference: 21564556517.008.10109002.06EPA 3958582
EA*5X30M17A*+ furnace: *96VTN0801716B*AHRI reference: 21564609517.008.10110002.06EPA 3958629
EA*5X30M17A*+ furnace: *80CTL0701716B*AHRI reference: 21564558717.008.10109002.06EPA 3958666
EA*5X30M17A*+ furnace: *80CTL0901716B*AHRI reference: 21564560817.008.10109002.06EPA 3958673
EA*5X30M17A*+ furnace: *80VTL0451412B*AHRI reference: 21564563117.008.10109002.06EPA 3958689
EA*5X30M17A*+ furnace: *80VTL0701716B*AHRI reference: 21564567017.008.10110002.06EPA 3958727
EA*5X30M17A*+ furnace: *95CSU0601716B*AHRI reference: 21564570317.007.80110002.06EPA 3958747
EA*5X30M17A*+ furnace: *97CMN0801714B*AHRI reference: 21564574717.008.10110002.06EPA 3958781
EA*5X30M17A*+ furnace: *96VSN0801716B*AHRI reference: 21564584017.008.10110002.06EPA 3958844
EA*5X30M17A*+ furnace: OMV112K14AAHRI reference: 21564615617.008.10112002.02EPA 3958910
EA*5X36M17A*+ furnace: *80CSU0401712A*AHRI reference: 21564617617.007.80110002.06EPA 3958916
EA*5X30M17A*+ furnace: *95MSU0601716A*AHRI reference: 21564589217.007.80110002.04EPA 3958948

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.