Airquest / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 7

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *97CMN0801714B*AHRI reference: 21564826217.508.10112002.08EPA 3961351
EA*5X37M21A*+ furnace: *97CMN0802120B*AHRI reference: 21564828217.508.10111002.10EPA 3961365
EA*5X37M21A*+ furnace: *97CMN1002122B*AHRI reference: 21564830217.508.10111002.10EPA 3961379
EA*5X37M21A*+ furnace: *96VSN0801716B*AHRI reference: 21564836217.508.10112002.08EPA 3961423
EA*5X37M21A*+ furnace: *95MSU0401712A*AHRI reference: 21564842617.508.10112002.08EPA 3961466
EA*5X37M21A*+ furnace: *95MSU0601716A*AHRI reference: 21564845217.508.10111002.10EPA 3961475
EA*5X37M21A*+ furnace: *95MSU0802120A*AHRI reference: 21564847517.508.10111002.10EPA 3961496
EA*5X37M21A*+ furnace: *96CTN0601714B*AHRI reference: 21564854117.508.10112002.10EPA 3961645
EA*5X37M21A*+ furnace: *96VTN0801716B*AHRI reference: 21564868017.508.10112002.08EPA 3961678
EA*5X37M21A*+ furnace: OMV098J12*AHRI reference: 21564878817.508.10115002.06EPA 3961751
EA*5X37M21A*+ furnace: OMV112K14AAHRI reference: 21564880817.508.10115002.18EPA 3961771
EA*5X25M17A*+ furnace: *80CSU0601716B*AHRI reference: 21572042917.508.00110002.10EPA 3980241
EA*5X25M17A*+ furnace: *97VTN0601716A*AHRI reference: 21572047417.508.00112002.08EPA 3980243
EA*5X25M17A*+ furnace: *97VTN0801716A*AHRI reference: 21572049217.508.00111002.08EPA 3980322
EA*5X25M17A*+ furnace: *97CTN0801716A*AHRI reference: 21572045717.508.00111002.08EPA 3980377
EA*5X37M17A*+ furnace: *97CTN0801716A*AHRI reference: 21572073317.508.00111002.08EPA 3981305
EA*5X37M21A*+ furnace: *80CSU0802120B*AHRI reference: 21572081117.508.00110002.12EPA 3981382
EA*5X37M21A*+ furnace: *97CTN0601716A*AHRI reference: 21572083917.508.00112002.08EPA 3981411
EA*5X37M21A*+ furnace: *97CTN0801716A*AHRI reference: 21572085317.508.00112002.10EPA 3981422
EA*5X37M21A*+ furnace: *97CTN0802120A*AHRI reference: 21572086717.508.00112002.10EPA 3981548