Airquest / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 25

514 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5514 / 514
EER2 · BTU/Wh11.5–14514 / 514
HSPF2 · BTU/Wh7.8–8.5514 / 514
Cooling capacity · BTU/h22,200–25,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000514 / 514
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500514 / 514
COP at 5°F / −15°C1.9–2.24514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingTwo-stage514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X30M14A*+ furnace: *96CTN0401410B*AHRI reference: 21564531016.008.00111002.00EPA 3997630 →
EA*5X36M17A*+ furnace: *97CTN0401410A*AHRI reference: 21799192316.008.00113002.02EPA 4566273 →
EA*5X36M17A*+ furnace: *97VTN0401410A*AHRI reference: 21799175816.008.00112002.02EPA 4566335 →
EA*5X37M17A*+ furnace: *97CTN0401410A*AHRI reference: 21799193716.008.00113002.04EPA 4566408 →
EA*5X24M17A*+ furnace: *97VTN0601412A*AHRI reference: 21799136816.008.00111002.04EPA 4566475 →
EA*5X24M17A*+ furnace: *97VTN0401712A*AHRI reference: 21799151216.008.00113002.00EPA 4566539 →
ESH5X30M12A*+ furnace: *96CTN0802120B*AHRI reference: 21565139415.507.80111002.06EPA 3719661 →
EA*5X25M17A*+TDRAHRI reference: 21564309015.507.80111001.96EPA 3956924 →
EA*5X37M21A*+TDRAHRI reference: 21564322915.507.80111001.94EPA 3956944 →
EA*5X24M14A*+ furnace: *96CTN0401410B*AHRI reference: 21564349215.507.80113002.00EPA 3957038 →
EA*5X24M14A*+ furnace: *96VTN0401410B*AHRI reference: 21564353415.508.10112002.02EPA 3957060 →
EA*5X24M17A*+ furnace: *96VSN0401410B*AHRI reference: 21564395415.507.80114002.00EPA 3957492 →
EA*5X24M17A*+ furnace: *96VTN0401410B*AHRI reference: 21564418015.507.80113001.98EPA 3957636 →
ESH5X30M12A*+ furnace: *80CSU0802120B*AHRI reference: 21572100015.507.80110002.08EPA 3980821 →
ESH5X30M12A*+ furnace: *97CTN0802120A*AHRI reference: 21572104215.507.80111002.06EPA 3980865 →
ESH5X30M12A*+ furnace: *97CTN1002122A*AHRI reference: 21572105615.507.80110002.08EPA 3980880 →
ESH5X30M12A*+ furnace: *97CTN1202422A*AHRI reference: 21572107015.507.80110002.06EPA 3981027 →
ESH5X30M12A*+ furnace: *97VTN0601716A*AHRI reference: 21572108715.507.80111002.06EPA 3981040 →
ESH5X30M12A*+ furnace: *97VTN0802120A*AHRI reference: 21572112315.507.80111002.06EPA 3981078 →
ESH5X30M12A*+ furnace: *97VTN1002120A*AHRI reference: 21572113915.507.80110002.08EPA 3981956 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →