Airquest / AIR-SOURCE HEAT PUMP

HVH837GKA2*+TSTAT

DELUXE 19 VS HP 2-STAGE

65 published source records · source checked Sep 21, 2026

SEER2 range17–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity31,600–33,000BTU/h

Each efficiency range summarizes published EPA records for HVH837GKA2*+TSTAT. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 65 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–1865 / 65
EER2 · BTU/Wh11.7–1265 / 65
HSPF2 · BTU/Wh8.1–8.565 / 65
Cooling capacity · BTU/h31,600–33,00065 / 65
Heating capacity at 47°F / 8.3°C · BTU/h46,000–48,00065 / 65
Heating capacity at 17°F / −8.3°C · BTU/h30,200–31,00065 / 65
Heating capacity at 5°F / −15°C · BTU/h24,000–24,40065 / 65
COP at 5°F / −15°C1.94–1.9865 / 65
Equipment / loop typeHP - Split System65 / 65
Refrigerant / source-reported GWPR-410A (GWP:2088)65 / 65
Compressor stagingTwo-stage65 / 65
Connected capabilityNo65 / 65

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EN(A,D,W)4X60L24**+ furnace: *80VSL0902420A*AHRI reference: 21046499318.008.10242001.96EPA 2417029 →
EN(A,D,W)4X60L24**+ furnace: *96VTN1002122A*AHRI reference: 21046493818.008.10240001.94EPA 2417652 →
EA*4X61L24A*+ furnace: *80VSL0902120A*AHRI reference: 21046180518.008.10244001.98EPA 2633302 →
EA*4X61L24A*+ furnace: *96VTN0802120A*AHRI reference: 21046196218.008.10244001.98EPA 2633310 →
EA*4X61L21A*+ furnace: *80VTL0902120A*AHRI reference: 21046142818.008.10244001.98EPA 2633319 →
EA*4X61L24A*+ furnace: *96VTN1002120A*AHRI reference: 21046197318.008.10244001.96EPA 2633325 →
EA*4X61L24A*+ furnace: *80VTL0902120A*AHRI reference: 21046183818.008.10244001.98EPA 2633351 →
EA*4X61L21A*+ furnace: *96VTN1002122A*AHRI reference: 21046132718.008.10242001.96EPA 2633353 →
EA*4X61L21A*+ furnace: *80VSL0902120A*AHRI reference: 21046141518.008.10244001.98EPA 2633359 →
EA*4X61L24A*+ furnace: *96VTN1202422A*AHRI reference: 21046185218.008.10242001.96EPA 2633379 →
EA*4X61L24A*+ furnace: *96VSN1002120A*AHRI reference: 21046173818.008.10242001.96EPA 2633425 →
EA*4X61L24A*+ furnace: *96VTN1002122A*AHRI reference: 21046176118.008.10242001.98EPA 2633429 →
EA*4X61L24A*+ furnace: *96VSN1202422A*AHRI reference: 21046174918.008.10242001.98EPA 2633444 →
EA*4X60L24A*+ furnace: *96VTN1002122A*AHRI reference: 21046098218.008.10242001.96EPA 2633455 →
EN(A,D,W)4X60L24**+ furnace: *80VSL0902120A*AHRI reference: 21046498217.508.10240001.94EPA 2416842 →
EN(A,D)4X48L24**+ furnace: *80VSL1102422A*AHRI reference: 21046468117.508.10242001.94EPA 2416856 →
EN(A,D)4X48L24**+ furnace: *96VTN1002122A*AHRI reference: 21046461517.508.10242001.96EPA 2417005 →
EN(A,D,W)4X48L21**+ furnace: *96VTN1002122A*AHRI reference: 21046417017.508.10242001.96EPA 2417020 →
EN(A,D,W)4X60L24**+ furnace: *80VSL1102422A*AHRI reference: 21046500417.508.10240001.96EPA 2417212 →
EN(A,D,W)4X60L24**+ furnace: *80VTL0902120A*AHRI reference: 21046501517.508.10240001.94EPA 2417232 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.