Airquest / AIR-SOURCE HEAT PUMP

H5H8T48*K*AAA*

Mainline 18 SEER2 HP · source records, page 7

415 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for H5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18415 / 415
EER2 · BTU/Wh11.7–13.5415 / 415
HSPF2 · BTU/Wh7.8–8.5415 / 415
Cooling capacity · BTU/h45,500–50,500415 / 415
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500415 / 415
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400415 / 415
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600415 / 415
COP at 5°F / −15°C2.1–2.34415 / 415
Equipment / loop typeHP - Split System415 / 415
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)415 / 415
Compressor stagingTwo-stage415 / 415
Connected capabilityNo415 / 415

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21635075917.008.10250002.14EPA 3805509
EVM5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21635002317.008.10248002.14EPA 3805538
FTMA5B48L0C*AHRI reference: 21635398417.008.10246002.30EPA 3805550
FCMA5B48L0C*+WALLCONAHRI reference: 21635399217.008.00246002.28EPA 3805561
EVM5X60M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635005517.008.10246002.14EPA 3805606
EVM5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635006317.008.10244002.16EPA 3805614
EVD5X61M24A*+ furnace: *96VTN0802120B*AHRI reference: 21635143217.008.50256002.22EPA 3805681
EVD5X61M24A*+ furnace: *96VTN1002120B*AHRI reference: 21635144017.008.10252002.14EPA 3805689
EVD5X60M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635080717.008.10246002.16EPA 3805778
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635081517.008.10244002.16EPA 3805786
EVD5X60M21A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 21635082317.008.00238002.16EPA 3805796
EVD5X60M21A*+WALLCON+ furnace: *97CMN0802120B*AHRI reference: 21635084717.008.00236002.18EPA 3805812
EVD5X61M24A*+ furnace: *97VTN0802120A*AHRI reference: 21635150417.008.00256002.10EPA 3805868
EVD5X61M24A*+ furnace: *97VTN1002120A*AHRI reference: 21635151217.008.00252002.12EPA 3805876
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21635015117.008.00238002.18EPA 3805920
EVD5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635031917.008.00234002.18EPA 3806323
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*AHRI reference: 21635021517.008.00238002.18EPA 3806385
EVD5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21635100717.008.50248002.26EPA 3806488
EVM5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634951117.008.10240002.16EPA 3806552
EVM5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21634953517.008.00234002.18EPA 3806568

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.