Airquest / AIR-SOURCE HEAT PUMP

H5H8T48*K*AAA*

Mainline 18 SEER2 HP

415 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for H5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18415 / 415
EER2 · BTU/Wh11.7–13.5415 / 415
HSPF2 · BTU/Wh7.8–8.5415 / 415
Cooling capacity · BTU/h45,500–50,500415 / 415
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500415 / 415
Heating capacity at 17°F / −8.3°C · BTU/h29,400–32,400415 / 415
Heating capacity at 5°F / −15°C · BTU/h23,200–26,600415 / 415
COP at 5°F / −15°C2.1–2.34415 / 415
Equipment / loop typeHP - Split System415 / 415
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)415 / 415
Compressor stagingTwo-stage415 / 415
Connected capabilityNo415 / 415

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FTMA5B60L0D*AHRI reference: 21615273818.008.10246002.34EPA 3802017
EVD5X61M24A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635134418.008.00236002.18EPA 3803598
EVD5X61M24A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21635141618.008.00236002.18EPA 3803965
EVD5X61M24A*+WALLCON+ furnace: *80CTL1352422B*AHRI reference: 21635130418.008.00234002.18EPA 3803997
EVD5X61M24A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635129618.008.00234002.18EPA 3804095
EVD5X61M24A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 21635147218.008.00236002.18EPA 3804101
EVD5X61M24A*+WALLCON+ furnace: *96CTN1202422B*AHRI reference: 21635142418.008.00236002.18EPA 3805673
EVD5X61M24A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21635146418.008.00234002.20EPA 3805700
EVD5X61M24A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21635148818.008.00236002.18EPA 3805711
EVD5X61M24A*+WALLCON+ furnace: *97CTN1202422A*AHRI reference: 21635149618.008.00236002.18EPA 3805860
EVD5X61M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635105518.008.00236002.18EPA 3806180
EVD5X61M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635106318.008.00236002.18EPA 3806440
EVD5X61M21A*+WALLCON+ furnace: *80CSU1002120A*AHRI reference: 21635099918.008.00252002.10EPA 3806480
EVD5X61M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21635120818.008.00234002.20EPA 3807227
QFVA5D6021X*AHRI reference: 21869562118.008.50258002.32EPA 4683206
EVD5X61M21A*+WALLCON+ furnace: *97CMN0802120B*AHRI reference: 21635111217.508.00238002.18EPA 3803292
EVD5X61M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635112017.508.00236002.18EPA 3803300
EVD5X61M21A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21635116817.508.00238002.18EPA 3803321
EVD5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21635120017.508.50246002.28EPA 3803338
EVM5X49M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21634981517.508.00236002.18EPA 3803424

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.