Airquest / AIR-SOURCE HEAT PUMP

H5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 22

498 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for H5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X24M12A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21636705716.007.80112002.00EPA 3810266 →
ESH5X30M12A*+ furnace: *80VSL1352422B*AHRI reference: 21636761716.007.80110002.02EPA 3810282 →
ESH5X30M12A*+WALLCON+ furnace: *80CTL0451712B*AHRI reference: 21636765716.008.00113002.06EPA 3810326 →
EA*5X24M17A*+ furnace: *96VSN0401712B*AHRI reference: 21636470416.008.10113002.02EPA 3810353 →
ESH5X30M12A*+WALLCON+ furnace: *80CSU1002120A*AHRI reference: 21636756116.007.80112002.00EPA 3810379 →
EA*5X24M17A*+ furnace: OLV098A12*AHRI reference: 21636481616.008.10113002.02EPA 3810560 →
EA*5X24M17A*+ furnace: OMV098J12*AHRI reference: 21636482416.008.10113002.04EPA 3810568 →
EA*5X30M17A*+ furnace: *96VSN0401410B*AHRI reference: 21636542416.007.80112001.96EPA 3810617 →
EA*5X30M17A*+ furnace: *96VSN0401712B*AHRI reference: 21636543216.008.10112002.06EPA 3810625 →
ESH5X24M12A*+WALLCON+ furnace: *80CTL1352422B*AHRI reference: 21636706516.007.80112002.00EPA 3810710 →
ESH5X24M12A*+ furnace: *80VTL0451412B*AHRI reference: 21636707316.007.80110002.02EPA 3810717 →
ESH5X36M12A*+ furnace: *96VTN0401712B*AHRI reference: 21636869116.007.80112002.00EPA 3810816 →
ESH5X24M12A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21636704916.007.80112002.00EPA 3810907 →
ESH5X24M12A*+WALLCON+ furnace: *97CMN1202422B*AHRI reference: 21636716916.007.80112002.00EPA 3810910 →
EA*5X30M17A*+WALLCON+ furnace: *96CTN0401410B*AHRI reference: 21636548016.007.80113001.96EPA 3811092 →
EA*5X30M17A*+ furnace: *96VTN0401712B*AHRI reference: 21636551216.007.80112001.98EPA 3811124 →
ESH5X24M12A*+WALLCON+ furnace: *95CSU0601716B*AHRI reference: 21636710516.007.80112002.00EPA 3811190 →
ESH5X24M12A*+WALLCON+ furnace: *95CSU0802120B*AHRI reference: 21636711316.007.80112002.00EPA 3811198 →
ESH5X24M12A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21636712116.007.80112002.00EPA 3811207 →
ESH5X24M12A*+WALLCON+ furnace: *97CMN0601714B*AHRI reference: 21636712916.007.80113001.98EPA 3811215 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →