SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for H5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+WALLCON+ furnace: *80CSU0601716B*AHRI reference: 21636680118.008.10112002.12EPA 3809683
EA*5X37M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21636680918.008.50112002.24EPA 3809690
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 21636688918.008.50112002.22EPA 3810020
EA*5X25M17A*+ furnace: *80VSL0701412B*AHRI reference: 21636491218.008.10110002.12EPA 3810361
EA*5X25M17A*+ furnace: *80VSL0701716B*AHRI reference: 21636492018.008.10111002.12EPA 3810409
EA*5X25M17A*+WALLCON+ furnace: *80CSU0401712A*AHRI reference: 21636488818.008.10112002.12EPA 3810428
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 21636493618.008.10111002.12EPA 3810447
EA*5X37M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21636684918.008.10112002.12EPA 3810743
EA*5X37M21A*+ furnace: *97VTN0802120A*AHRI reference: 21636687318.008.50112002.22EPA 3810767
EA*5X37M21A*+WALLCON+ furnace: *80CTL0901716B*AHRI reference: 21636649718.008.10112002.12EPA 3810878
EA*5X37M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21636650518.008.10112002.12EPA 3810885
EA*5X37M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21636651318.008.10112002.12EPA 3810893
EA*5X37M21A*+ furnace: *80VTL0701716B*AHRI reference: 21636652118.008.10111002.12EPA 3810902
EA*5X37M21A*+ furnace: *80VSL0901716B*AHRI reference: 21636641718.008.10111002.12EPA 3811008
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 21636643318.008.50111002.22EPA 3811024
EA*5X37M21A*+ furnace: *80MSU0401712A*AHRI reference: 21636644118.008.50111002.24EPA 3811032
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21636644918.008.50112002.24EPA 3811040
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 21636645718.008.50111002.24EPA 3811048
EVD5X38M17A*+ furnace: *96VSN0601716B*AHRI reference: 21636428018.007.80111002.04EPA 3811243
EVD5X38M17A*+ furnace: *96VTN0601716B*AHRI reference: 21636433618.007.80111002.04EPA 3811447