Airquest / AIR-SOURCE HEAT PUMP

H5H6S19*K*AAA*

MAINLINE 16 SEER2 HP · source records, page 2

76 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,700–19,300BTU/h

Each efficiency range summarizes published EPA records for H5H6S19*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 76 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1676 / 76
EER2 · BTU/Wh12.5–1376 / 76
HSPF2 · BTU/Wh7.8–876 / 76
Cooling capacity · BTU/h17,700–19,30076 / 76
Heating capacity at 47°F / 8.3°C · BTU/h18,400–19,50076 / 76
Heating capacity at 17°F / −8.3°C · BTU/h10,300–11,00076 / 76
Heating capacity at 5°F / −15°C · BTU/h7,900–8,50076 / 76
COP at 5°F / −15°C1.9–276 / 76
Equipment / loop typeHP - Split System76 / 76
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)76 / 76
Compressor stagingSingle stage76 / 76
Connected capabilityNo76 / 76

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X25M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21772248116.008.0083002.00EPA 4509657 →
EA*5X25M17A*+ furnace: *80VSL0451412B*AHRI reference: 21772248916.008.0084002.00EPA 4509665 →
EA*5X25M17A*+ furnace: *80VSL0701412B*AHRI reference: 21772249716.008.0084002.00EPA 4509673 →
EA*5X25M17A*+ furnace: *80VSL0701716B*AHRI reference: 21772250516.008.0084002.00EPA 4509681 →
EA*5X25M17A*+ furnace: *80VSL0901716B*AHRI reference: 21772251316.008.0084002.00EPA 4509689 →
EA*5X25M17A*+WALLCON+ furnace: *97CMN0801714B*AHRI reference: 21772260116.008.0084002.00EPA 4509749 →
EA*5X25M17A*+ furnace: *92MSN0601412A*AHRI reference: 21772261716.008.0083002.00EPA 4509757 →
EA*5X25M17A*+ furnace: *92MSN0601714A*AHRI reference: 21772262516.008.0084002.00EPA 4509765 →
EA*5X25M17A*+ furnace: *92MSN0801716A*AHRI reference: 21772263316.008.0083002.00EPA 4509773 →
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21772272216.008.0084002.00EPA 4509842 →
EA*5X25M17A*+WALLCON+ furnace: *80CTL0451712B*AHRI reference: 21772253715.508.0084002.00EPA 4509078 →
EA*5X25M17A*+WALLCON+ furnace: *80CTL0701716B*AHRI reference: 21772255315.508.0084002.00EPA 4509095 →
EA*5X25M17A*+WALLCON+ furnace: *80CTL0901716B*AHRI reference: 21772256115.508.0084002.00EPA 4509103 →
EA*5X25M17A*+WALLCON+ furnace: *95CSU0601716B*AHRI reference: 21772258515.507.8084001.90EPA 4509127 →
EA*5X19M17A*+ furnace: *95MSU0601716A*AHRI reference: 21772172815.507.8084001.90EPA 4509131 →
EA*5X19M17A*+WALLCON+ furnace: *96CTN0601714B*AHRI reference: 21772174415.508.0084002.00EPA 4509140 →
EA*5X19M17A*+WALLCON+ furnace: *97CTN0801716A*AHRI reference: 21772176815.508.0084002.00EPA 4509156 →
EA*5X25M17A*+WALLCON+ furnace: *96CTN0601714B*AHRI reference: 21772273815.508.0084002.00EPA 4509171 →
EA*5X25M17A*+WALLCON+ furnace: *97CTN0601716A*AHRI reference: 21772275415.508.0084002.00EPA 4509187 →
EA*5X25M17A*+WALLCON+ furnace: *97CTN0801716A*AHRI reference: 21772276215.508.0084002.00EPA 4509195 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →