Airquest / AIR-SOURCE HEAT PUMP

H5H3V60*K*AAA*

Deluxe 23 VS Heat Pump · source records, page 3

55 published source records · source checked Sep 21, 2026

SEER2 range17–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity55,000–58,000BTU/h

Each efficiency range summarizes published EPA records for H5H3V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 55 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–2055 / 55
EER2 · BTU/Wh10.5–12.555 / 55
HSPF2 · BTU/Wh7.8–8.555 / 55
Cooling capacity · BTU/h55,000–58,00055 / 55
Heating capacity at 47°F / 8.3°C · BTU/h60,000–63,50052 / 55
Heating capacity at 17°F / −8.3°C · BTU/h46,000–49,00055 / 55
Heating capacity at 5°F / −15°C · BTU/h41,000–47,50055 / 55
COP at 5°F / −15°C1.95–2.0855 / 55
Equipment / loop typeHP - Split System55 / 55
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)55 / 55
Compressor stagingContinuously variable55 / 55
Connected capabilityNo55 / 55

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21593173718.008.50475002.00EPA 3727585 →
ESH5X60M12A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 21593180718.008.10460001.95EPA 3728054 →
ESH5X60M12A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 21593179718.008.10455001.95EPA 3729427 →
ESH5X60M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21593182718.008.10455002.00EPA 3729593 →
ESH5X60M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21593183718.008.10460002.00EPA 3729603 →
ESH5X60M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21593185718.008.10455002.00EPA 3729623 →
ESH5X60M12A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21593188718.008.10460001.95EPA 3731470 →
ESH5X60M12A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21593190718.008.10460001.95EPA 3731537 →
ESH5X60M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21593191718.008.10460001.95EPA 3731547 →
EA*5X60M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21593159717.508.10470001.95EPA 3726365 →
ESH5X60M12A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21593181717.508.10465001.95EPA 3728064 →
ESH5X60M12A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21593184717.508.10460001.95EPA 3729613 →
ESH5X60M12A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21593187717.508.10460001.95EPA 3729643 →
ESH5X60M12A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21593189717.508.10460001.95EPA 3731527 →
ESH5X60M12A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21593186717.008.10470001.95EPA 3729633 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →