H5H3V36*K*AAA*
Deluxe 23 VS Heat Pump · source records, page 14
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 539 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.14 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X48M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215940737 | 21.00 | 8.50 | 28400 | 2.04 | EPA 3736028 → |
EVM5X44M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 215942373 | 21.00 | 8.50 | 28000 | 2.06 | EPA 3736086 → |
EVM5X49M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 215942383 | 21.00 | 8.50 | 28000 | 2.06 | EPA 3736096 → |
EVM5X49M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 215942393 | 21.00 | 8.50 | 28000 | 2.06 | EPA 3736108 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 215942403 | 21.00 | 8.50 | 28000 | 2.06 | EPA 3736117 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 215942413 | 21.00 | 8.50 | 28000 | 2.06 | EPA 3736127 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 215940837 | 21.00 | 8.50 | 29000 | 2.00 | EPA 3736210 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 215940847 | 21.00 | 8.50 | 29000 | 2.00 | EPA 3736221 → |
EVM5X44M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 215942363 | 21.00 | 8.50 | 28000 | 2.06 | EPA 3737465 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 215942453 | 21.00 | 8.50 | 28000 | 2.06 | EPA 3737520 → |
EVD5X60M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 215942463 | 21.00 | 8.50 | 28000 | 2.00 | EPA 3737530 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215932667 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3724447 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215932707 | 20.50 | 9.00 | 26200 | 1.96 | EPA 3724487 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215932717 | 20.50 | 9.00 | 26200 | 1.96 | EPA 3724497 → |
FCMA5B36L0C*+WALLCONCold climate designationAHRI reference: 215933957 | 20.50 | 9.50 | 26800 | 2.00 | EPA 3724661 → |
EVD5X36M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 215935757 | 20.50 | 8.10 | 27000 | 1.95 | EPA 3724772 → |
EVD5X36M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 215935767 | 20.50 | 8.50 | 28400 | 2.02 | EPA 3724782 → |
EVD5X37M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 215935787 | 20.50 | 8.50 | 27600 | 2.08 | EPA 3724802 → |
EVD5X37M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 215935797 | 20.50 | 8.50 | 27600 | 2.06 | EPA 3724836 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215939837 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3724933 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.